The Feasibility and Efficiency of Volumetric Modulated Arc Therapy-Based Breath Control Stereotactic Body Radiotherapy for Liver Tumors

Author:

Qiu Jian-Jian1,Ge Weiqiang1,Zhang Libo1,Yao Ye1,Zheng Xiangpeng1

Affiliation:

1. Department of Radiation Oncology, Huadong Hospital, Fudan University, Shanghai, China

Abstract

There are strong evidences showing the promising oncologic results of stereotactic body radiotherapy for liver tumors. This study aims to investigate the feasibility, plan quality, and delivery efficiency of image-guided volumetric modulated arc therapy-based voluntary deep exhale breath-holding technique in the stereotactic body radiotherapy for liver tumors. Treatment was planned using volumetric modulated arc therapy with 2 modified partial arc and replanned using intensity modulated radiation therapy technique for comparison. Dosimetric parameters were calculated for plan quality assessment. Quality assurance studies included both point and multiple planar dose verifications. Daily cone beam computed tomography imaging was used to measure and correct positional errors for target volumes and critical structures immediately prior to and during treatment delivery. Total monitor units and delivery times were also evaluated. No significant dosimetric difference was found between volumetric-modulated arc therapy and conventional intensity modulated radiation therapy plans. Both techniques were able to minimize doses to organs at risk including normal liver, kidneys, spinal cord, and stomach. However, the average monitor units with volumetric-modulated arc therapy were significantly lower (29.2%) than those with intensity modulated radiation therapy ( P = .012). The average beam-on time in volumetric-modulated arc therapy plans was 22.2% shorter than that in intensity modulated radiation therapy plans. In conclusion, it is feasible to utilize volumetric modulated arc therapy in the treatment planning of stereotactic body radiotherapy for liver tumors under breath control mode. In comparison to conventional intensity modulated radiation therapy plans, volumetric modulated arc therapy plans are of high efficiency with less monitor units, shorter beam-on time, tolerable intrafractional errors as well as better dosimetrics, meriting further investigations, and clinical evaluations.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3