Early failure of an uncemented femoral stem, as compared to two other stems with similar design, following primary total hip arthroplasty performed with direct anterior approach

Author:

Macheras George A1,Lepetsos Panagiotis1,Galanakos Spyridon P1,Papadakis Stamatios A1,Poultsides Lazaros A2,Karachalios Theofilos S3

Affiliation:

1. 4th Department of Trauma and Orthopaedics, KAT Hospital, Athens, Greece

2. 3rd Academic Department of Orthopaedics and Trauma, Aristotle University Medical School, Thessaloniki, Greece

3. Department of Orthopaedics, University General Hospital of Larissa, Larissa, Greece

Abstract

Introduction: An increased risk of early femoral component loosening has been reported using the direct anterior approach (DAA) compared with other common surgical approaches. However, long-term data are scarce. The purpose of this study is: (1) to determine the incidence of early femoral loosening in a high volume, single surgeon’s practice utilising the DAA approach; and (2) to examine the effect of stem design and type of coating on aseptic loosening in the early and mid-term postoperative period. Methods: A retrospective review of 1650 consecutive patients (1800 hips) who underwent total hip arthroplasty (THA) using the DAA between August 2011 and December 2017 was conducted at our institution. 3 types of uncemented femoral stems (Quadra-S, Avenir, TwinSys), with similar design, but different coating, were implanted. Patients were evaluated clinically and radiologically at 4 weeks, 3 months, 1 year, and annually thereafter. Results: After a mean follow-up of 46.4 months, the total incidence of revision for aseptic loosening was 0.44% ( n = 8). All loose stems were Quadra-S, failing to achieve osseointegration, for an overall incidence of 0.96% ( p = 0.002). None of the other stems were loose. Radiolucent lines around the proximal stem portion were visible in 75 Quadra-S stems (4.1%) on radiographs taken at 1 year postoperatively and continued to deteriorate at the latest follow-up. Conclusions: In this specific cohort of patients, the increased rate of femoral stem aseptic loosening was implant-related and was attributed only to a specific type of femoral stem (Quadra-S). No relation to other factors was proven suggesting that the surface characteristics of this femoral stem and the lack of bioactive coating are responsible for the observed early femoral failures. These findings should be confirmed by additional registry work and larger population sample sizes are needed to evaluate the prosthesis performance after implantation through the DAA.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3