Primary Tritanium acetabular components have increased rates of radiolucency associated with inferior clinical outcomes at short-term follow-up

Author:

Bingham Joshua S1,Hinckley Nathaniel B1,Deckey David G1ORCID,Hines Jeremy2,Spangehl Mark J1

Affiliation:

1. Department of Orthopaedics, Mayo Clinic Arizona, Phoenix, AZ, USA

2. Department of Orthopaedics, Mayo Clinic Rochester, Rochester, MN, USA

Abstract

Introduction: Cementless fixation is the standard for acetabular fixation in primary total hip arthroplasty (THA). There are various surface finishes thought to improve osteointegration, although literature regarding the long-term survival of some of these surfaces is limited. Regardless of design, primary stability is essential to allow for osteointegration. Previous studies have suggested an increased rate of radiolucency and compromised short-term functional outcomes using the Tritanium primary acetabular component (Stryker, Mahwah, NJ). The purpose of this study was to compare the primary Tritanium acetabular component to another contemporary acetabular component as a control group with an established clinical record. Methods: 444 consecutive, primary THAs performed by a single surgeon from 2008 to 2012 were reviewed. Patients were included if they had a minimum 1-year follow-up. Implant survivorship and modified Harris Hip Scores (mHHS) were recorded for all patients at final follow-up. Radiographs were evaluated by 2 surgeons at 6 weeks, 1 year, and the most recent follow-up for evidence of radiolucency and migration. Components were considered to have evidence of radiographic lucency if they had radiolucency in 2 or more DeLee zones. Results: 198 patients met criteria for inclusion (96 Pinnacle, 102 Tritanium). Average follow-up was 28 (12–72) months. At final follow-up 6.2% of the Pinnacle cups and 29.4% of the Tritanium cups had radiographic evidence of loosening ( p < 0.01). The average mHHS for the Tritanium group was 83.1, and 88.4 for the Pinnacle group ( p < 0.01). Radiographic evidence of loosening also correlated with a lower mHHS: 75.5 versus 86.4 ( p < 0.01). In patients that received Tritanium cups without screw fixation 44.6% showed radiographic evidence of loosening versus 8% that received screw fixation ( p < 0.01). In total, 6 patients in the Tritanium group required revision for aseptic loosening of the acetabular component. Conclusions: The 30% rate of radiographic loosening in the Tritanium group was significantly higher than the Pinnacle group and correlated with an inferior clinical outcome. Interestingly the use of screw augmentation was protective against radiographic evidence of loosening. This suggests that the Tritanium component may be prone to fibrous in-growth because of inadequate primary stability.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3