Affiliation:
1. Department of Lower Limb Surgery, Wrightington Wigan and Leigh NHS Foundation Trust, Wigan, UK
Abstract
Background: Fully hydroxyapatite coated, double-tapered, titanium stems are the most commonly used uncemented implants in the UK with survivorship reported at 96.3% at 23 years however there is no literature on the consequences of revision. We aimed to explore the reasons for failure, ease of stem extraction, extent of bone loss and complexity of the subsequent reconstruction. Methods: Between December 2012 and March 2019, 104 cases requiring removal of the Corail® stem (DePuy Synthes, Warsaw, IN, USA) were identified from the National Joint Registry (NJR) and our local revision database. Indication for revision, surgical/reconstruction technique, complications and follow-up data were reviewed. Results: The common reasons for revision were aseptic loosening 45.2%, infection 23.5%, instability 4.8% and peri-prosthetic fracture 12.5%. Removal of the implant without extended trochanteric osteotomy (ETO) was achieved in 94.2% of cases. Of those revised for aseptic loosening 23% were proximal, 38% were proximal/mid stem and 38% all zones. Significant bone loss is not a common feature of the failure of this stem with 95% graded as a Paprosky grade 2 or less. In terms of reconstruction, 69.2% were revised to a primary cemented stem. Conclusions: In the majority of cases revision can be achieved without an ETO and reconstruction possible using a primary stem as significant bone loss is not a common feature of failure of this stem design. We conclude that this stem is safe to use in younger patients who may outlast any type of primary implant and would inevitably face revision in their lifetime.
Subject
Orthopedics and Sports Medicine,Surgery
Reference13 articles.
1. National Joint Registry for England, Wales, Northern Ireland and Isle of Man. 17th Annual Report 2020, https://reports.njrcentre.org.Uk/Portals/0/PDFdownloads/NJR%2017th%20Annual%20Report%202020.pdf (2020, accessed 21 April 2021).
2. Twenty-year results of the cementless Corail stem
3. GIRFT. Getting it right in orthopaedics reflecting on success and reinforcing improvement: a follow-up on the GIRFT national specialty report on orthopaedics. Data from the National Joint Registry and Orthopaedic Data Evaluation Panel Data from NHS Digital, https://gettingitrightfirsttime.co.uk/wp-content/uploads/2020/02/GIRFT-orthopaedics-follow-up-report-February-2020.pdf (2020, accessed 21 April 2021).
4. The Effect of Size for a Hydroxyapatite-Coated Cementless Implant on Component Revision in Total Hip Arthroplasty: An Analysis of 41,265 Stems
5. BYPASS FIXATION