Intraoperative radiation exposure in hip arthroscopy: a systematic review

Author:

Shah Ajay1,Nassri Mohammed2,Kay Jeffrey2,Simunovic Nicole2,Mascarenhas Vasco V3,Andrade Antonio J4,Marin-Peña Óliver R5,Ayeni Olufemi R26

Affiliation:

1. Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada

2. Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada

3. Musculoskeletal Imaging Unit, Department of Radiology, Hospital da Luz, Lisbon, Portugal

4. Reading Orthopaedic Centre, Circle Reading Hospital, Reading, UK

5. Orthopedic Surgery and Traumatology Department, University Hospital Infanta Leonor, Madrid, Spain

6. Department of Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, ON, Canada

Abstract

Fluoroscopy is used in hip arthroscopy (HA) for portal placement, instrument localisation, and guidance in bony resection. The recent increase in arthroscopic hip procedures may place patients and surgeons at risk for increased radiation exposure and radiation-induced complications. The purpose of the current systematic review was to assess intraoperative radiation exposure in HA. The systematic review was conducted according to PRISMA guidelines; inclusion criteria were studies assessing radiation exposure in HA. 9 studies including 994 patients were included. Mean age was 38.6 years and 48% (436 of 906) were female. Mean time of fluoroscopy exposure was 0.58 minutes. Dose area product was 129.5 cGycm2. Mean intraoperative absorbed radiation dose studies was 12.6 mGy. Mean intraoperative effective dose was 0.48 mSv. The mean occupational exposure to the surgeon per case was 0.0031 mSv. Higher patient body mass index (BMI) correlated to greater patient effective and cumulative dose ( p < 0.05, r = 0.404), and greater occupational exposure ( p < 0.001, r = 0.460). Increasing surgeon experience decreased fluoroscopy time ( p = 0.039) and radiation dose ( p = 0.002). Radiation dose and effective dose were well under the thresholds for deterministic effects (2 Gy) and annual radiation exposure for occupational workers (20 mSv). Intraoperative radiation exposure to patients and surgeons is within acceptable annual radiation limits. Ensuring careful selection of perioperative imaging modalities, proper protective shielding, specifically the use of leaded eyeglasses, and optimal C-arm positioning are key strategies to reduce radiation exposure to patients and surgeons alike.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3