Validation of a method to measure three-dimensional hip joint kinematics in subjects with femoroacetabular impingement

Author:

Ward Thomas R1,Hussain Mafruha M2,Pickering Mark2,Perriman Diana1,Burns Al1,Scarvell Jennie13,Smith Paul N14

Affiliation:

1. Trauma and Orthopaedic Research Unit, Canberra Hospital, ACT, Australia

2. University of New South Wales at The Australian Defence Force Academy, Australia

3. The University of Canberra, Australia

4. The Australian National University, Canberra, Australia

Abstract

Introduction: A kinematic measurement method combining dynamic motion and imaging, which captures the behaviour of the hip at terminal motion, may offer improved diagnostic accuracy and enhance our understanding of the mechanics of femoroacetabular impingement (FAI). Methods: 3 embalmed cadaveric hip/pelvis specimens with implanted Roentgen Stereophotogrammetric Analysis (RSA) beads were mounted on a custom rig and imaged with a fluoroscope in four poses to simulate a clinical impingement examination: in hip extension and in three positions: near impingement, early impingement and late impingement while simulating a flexion/adduction/internal rotation manoeuvre. Hip joint kinematics were measured using 2 methods and compared: RSA (gold standard) and a custom 3-dimensional to 2-dimensional (3D–2D) image registration method which matches 3D models developed from CT to 2D fluoroscopic images. Results: Using RSA as the gold standard, bias and precision of hip joint rotations measured using 3D–2D registration demonstrated maximums of 1.64° and 3.96°, respectively. However, if the single outlier was removed, bias and precision were 0.55° and 1.38°. Bias and precision of translations had maximums of 0.51 mm and 0.77 mm, respectively. Conclusions: This 3D to 2D registration method may offer a clinically useful solution for dynamic assessment of hip impingement. If 5-mm translation and 10° of rotation represent a clinically significant difference in hip kinematics, the method’s accuracy of approximately 1 mm displacement and 1° rotation should enable detection of significant clinical differences.

Funder

Avant Mutual

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3