Purpose: Modular stems in revision total hip arthroplasties allow diaphyseal fixation and optimal restoration of the architecture of the proximal femur. Several studies report metaphyseal implant breakage having a negative impact on survivorship. The aim of the study was to evaluate the outcome of an uncemented modular fluted tapered stem (MFT) in revision surgery. Methods: In a retrospective study, 316 patients who had revision surgery using the same design of MFT implant (Modular Revision Stem [MRS], Lima Corporate, Italy) between 2012 and 2017 were identified. Patients were male in 51% of cases and mean age was 74 years. Indications were 110 periprosthetic fractures, 98 periprosthetic joint infection, 97 aseptic loosening, 10 instability and 1 other cause. Survivorship, complications, clinical and radiographic outcomes, were assessed. Mean follow-up was 5 years. Results: There was no implant breakage. At 5-year follow-up, the survivorship, free from revision for aseptic loosening and free of revision for any reason were 96% and 87%, respectively. At last follow-up (8 years), these figures were 92% and 71%, respectively. 31 implants were revised. The risk of revision for any cause was higher for extreme length metaphyseal implants, hazard ratio was 3.7 (95% CI, 1.82–7.52). A mean stem subsidence of 9 mm was noted in 37 cases; 4 were revised for aseptic loosening. The Harris Hip Score at final follow-up was 82. Conclusions: At 5-year follow-up, the MFT implant showed a good survivorship and outcomes with no specific complications. Unlike literature reports, no specific complications occurred with this design. Stem junction positioning and therefore metaphyseal length may be key to optimise long-term survivorship. However, a longer follow-up is needed as implant breakage is more often seen after long implantation times.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3