Measurement of safe acetabular medial wall defect size in revision hip arthroplasty with a porous cup

Author:

Barbaric Starcevic Katarina1,Bicanic Goran2,Alar Zeljko3,Sakoman Matija3,Starcevic Damir4ORCID,Delimar Domagoj15

Affiliation:

1. Department of Orthopaedic Surgery, University Hospital Centre Zagreb, Zagreb, Croatia

2. Orthopedic Department, Al Habib Hospital Dubai, Dubai, UAE

3. Department of Materials, Laboratory for Testing Mechanical Properties, Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia

4. Special Hospital for Orthopaedic Surgery “Akromion”, Krapinske Toplice, Croatia

5. School of Medicine, University of Zagreb, Croatia

Abstract

Introduction: The majority of acetabular revisions can be performed with an uncemented, porous acetabular component with or without bone grafting. These are contained acetabular defects, with an intact acetabular rim (Paprosky type I and II). As defects of the medial wall of the acetabulum are a challenge situation revision surgery, we performed this biomechanical study on a pig pelvis model with contained acetabular defects to determine the size of medial wall defect at which the acetabular cup will have sufficient primary stability. Materials and methods: In 24 pig pelvis models, different diameter of medial wall defects were created, followed by acetabular component placement. The acetabulum externally loaded, and the force at a level in which the acetabular component remains stable for each diameter of defect, or at which point the acetabular cup moves into the pelvis for >2 mm. Results: In the models with acetabular medial wall defects of 10 and 20 mm, 2 mm acetabular displacement occurred under a force between 1000 and 1500 N. In those with a medial wall defect of 25 mm, the force that caused acetabular instability was between 700 and 1000 N. In the models with 30 mm of medial wall defect all acetabular components were unstable under a force of 700 N. Conclusions: According to our results, acetabular component should be stable if the defect of the medial wall of the acetabulum is less than 68% of the diameter of the acetabular component or if the uncovered surface area of the acetabular component is not greater than 27%, and the force <700 N. For a load of 1000 N, the medial wall defect should not exceed 45% of acetabular component diameter or 18% of uncovered acetabular component surface.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3