The impact of failed novel technology and technical errors on the revision burden in total hip arthroplasty: what percentage of revision hip arthroplasty was potentially avoidable?

Author:

Brown Matthew L1,Dunn Justin M2,Early Samuel3,Challa Sravya3,Ezzet Kace A4

Affiliation:

1. Department of Orthopaedic Surgery, St Luke’s University Health Network, Fountain Hill, PA, USA

2. Rome Orthopaedic Center, Rome, GA, USA

3. Shiley Center for Orthopaedic Research and Education at Scripps Clinic, La Jolla, CA, USA

4. Department of Orthopaedic Surgery, Scripps Clinic, La Jolla, CA, USA

Abstract

Background: Despite the high success rate of total hip arthroplasty (THA), new implant technologies continue to be developed. Although potentially useful, such novel developments may result in unintended consequences, leading to revision surgery, often prematurely. In several instances, new technology that appeared promising was later found to be inferior to existing technology and resulting in early revision surgery. Additionally, technical surgical errors may also lead to early revisions. Some have argued that revisions related to such phenomena are potentially avoidable. The present analysis investigates to what extent the contribution of “failed new technology” and “technical errors” contributes to the revision burden and to the need for premature revision arthroplasty. Methods: We retrospectively analysed 432 revision THAs and categorised them as either “late revisions” based on survivorship of 10 years or “premature revisions”. Among both cohorts, we determined what percentage of revisions were potentially avoidable and due to failed novel technologies and technical errors, and what percent were “unavoidable”. Results: Of the 432 revisions, 267 (62%) were considered premature and 38% were considered late. Of the premature revisions, 108 were considered potentially avoidable (81 failed novel technologies, 27 technical errors). Conclusions: Our data demonstrates that new technology and surgical techniques can result in premature failure of THA. Surgeons should take caution when incorporating new implant technology or surgical techniques into their practice.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3