Excellent mid-term outcomes with a hemispheric titanium porous-coated acetabular component for total hip arthroplasty: 7–10 year follow-up

Author:

Yeroushalmi David1ORCID,Singh Vivek1,Maher Nolan1,Gabor Jonathan A1,Zuckerman Joseph D1,Schwarzkopf Ran1

Affiliation:

1. NYU Orthopedic Hospital, NYU Langone Health, New York, NY, USA

Abstract

Introduction: Third-generation hemispheric, titanium porous-coated (HTPC) acetabular cups have been shown to achieve good biologic fixation through enhanced porous ingrowth surfaces. They also allow for a wide range of bearing options, including polyethylene, dual-mobility, and ceramic liners. The purpose of the study is to review the mid-term clinical outcomes an HTPC acetabular cup with a minimum of 7-year follow-up. Methods: A retrospective, observational study was conducted on all consecutive patients who underwent total hip arthroplasty (THA) with an HTCP acetabular cup at an urban, tertiary referral centre. Descriptive statistics were used describe baseline patient characteristics. Outcomes collected included postoperative complications, survival free of reoperations, and presence of osteolysis at latest imaging follow-up. Implant survival was analysed using the Kaplan-Meier method. Results: 118 cases (114 primary, 4 revision) underwent THA with the HTCP acetabular cup at an average follow-up of 8.16 ± 0.85 years (range 7.02–10.28 years). Mean patient age at the time of surgery was 61.29 ± 12.04 years. All cases utilised a high-molecular-weight polyethylene (HMWPE) liner. None of the acetabular cups showed loosening or migration at the latest follow-up. There were 2 revisions in our study, 1 for abductor mechanism disruption and 1 due to surgical site infection where the acetabular cup was revised. Kaplan-Meier survivorship analysis for all-cause revision at 7 and 10-year follow-up showed a survival rate of 99.1% (95% confidence interval, 94.1–99.9%). Survivorship analysis for aseptic acetabular revision at 10-year follow-up showed a survival rate of 100%. Conclusions: At long-term follow-up, no radiologic and minimal clinical complications were identified in this series. The HTPC acetabular cup system, used in conjunction with a HMWPE liner, demonstrates excellent outcomes and survivorship when compared to earlier mid-term studies published in the literature.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3