Introduction:Total hip arthroplasty (THA) is the 2nd most common total joint replacement surgery in the United States. However, not all THA devices perform well and need revised for several reasons including dislocation. Higher offset acetabular liners reduce this problem by creating a more anatomically/biomechanically natural hip joint, increasing soft-tissue tension, and accommodating larger femoral heads in smaller acetabular cups via increased polyethylene thickness. To our knowledge, however, in vivo wear (another failure mode) performance of offset acetabular liners remains unknown.Methods:2 cohorts of 40 individuals (0-mm, 4-mm offset acetabular liners, respectively) from a single surgeon’s consecutive caseload were assessed. 6-week/5-year post-op radiographs were compared using a validated method using SolidWorks software to assess in vivo linear and volumetric wear rates. Resultant surgical offset was also quantified using this method.Results:Linear wear rate for 0-mm and 4-mm offset cohorts were 0.01 ± 0.09 mm/year and 0.08 ± 0.12 mm/year, respectively. Volumetric wear rate for 0-mm and 4-mm offset cohorts were 30.4 ± 20.4 mm3/year and 61.6 ± 42.1 mm3/year, respectively. Both of these were statistically significant. Neither linear nor volumetric wear rate was correlated with resultant surgical offset.Discussion:To our knowledge, this is the 1st study to compare in vivo wear performance of 0-mm and 4-mm offset acetabular liners. Although linear and volumetric wear rates were different between cohorts, neither reached previously established osteolysis thresholds. Moreover, wear rates were not correlated with resultant surgical offset. Finally, no patients in either cohort showed signs of osteolysis nor needed revision. As such, the clinical relevance of the wear rate differences is potentially less significant.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3