Accuracy of digital templating in uncemented primary total hip arthroplasty: which factors are associated with accuracy of preoperative planning?

Author:

Adamczyk Andrew12,Laboudie Pierre12ORCID,Nessek Hamid2,Kim Paul R12,Gofton Wade T12,Feibel Robert12,Grammatopoulos George12ORCID

Affiliation:

1. Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON, Canada

2. Faculty of Medicine, University of Ottawa, Ontario, ON, Canada

Abstract

Background: Preoperative planning is a fundamental step for successful total hip arthroplasty (THA). Studies have highlighted the accuracy of preoperative digital templating for estimating acetabular cup and stem size. Stem design such as single-wedge metadiaphyseal (Type 1 stem) versus mid-short stem (microplasty) and surgical approach (anterior, direct lateral or posterior) have not been well investigated as predictors of THA templating accuracy. Methods: 204 patients (220 hips) who had undergone elective THA between November 2016 and December 2019 and presented a saved preoperative template were retrospectively reviewed. Templates from 5 different surgeons were involved in the analysis. 3 different approaches were used: direct lateral (DL), posterior (PA), direct anterior (DAA). 2 different stem designs were used: single-wedge metadiaphyseal and single-wedge mid-short (Biomet Taperloc Microplasty), while the acetabular component remained the same. Bivariate and multivariate regression analyses were performed to determine predictors of accuracy. Results: Femoral component size templating accuracy was significantly improved when using the single-wedge mid-short stem (Taperloc Microplasty) design when performing bivariate analysis. Although accuracy of cup sizing was not affected by approach, precision was significantly better in the PA group ( p < 0.05). Accuracy of templating was found to be independent of BMI and gender but dependent on presence of calibration marker and stem design ( p < 0.05). Conclusions: When striving for improved templating accuracy, acetabular and femoral component accuracy were best achieved using a calibration marker and a metaphyseal short femoral stem design.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3