Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion

Author:

Okamoto Masakazu1ORCID,Uchihara Yoshinobu1ORCID,Saito Kenichiro2,Inagaki Yusuke2,Mahakkanukrauh Pasuk34,Tanaka Yasuhito1

Affiliation:

1. Department of Orthopaedic Surgery, Nara Medical University, Kashihara, Nara, Japan

2. Department of Rehabilitation, Nara Medical University, Kashihara, Nara, Japan

3. Department of Anatomy Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand

4. Excellence Centre in Osteology Research and Training Centre (ORCT), Chiang Mai University, Chiang Mai, Thailand

Abstract

Background: Nerve injury is one of the most serious complications of total hip arthroplasty (THA). It is suspected to be a result from nerve compression or direct injury caused by an acetabular retractor. The anatomical relationship between the acetabular rim and the femoral and sciatic nerves, including hip motion, has not been investigated. This study aimed to identify the optimal position for retractor insertion during THA to prevent nerve damage. Methods: A total of 28 hip joints from 14 freshly frozen cadavers were used. Using an anterolateral approach, each cadaver was immobilised in the lateral decubitus position and deployed to measure the distance between the nerves and the acetabular rim, while the hip joint was changed to the extension, neutral, and flexion positions. Results: Three femoral nerves were closest to the anterior margin of the acetabulum at 90° and 120° of extension and farthest away at 30° of flexion. The sciatic nerve was closest to the posterior margin of the acetabulum at 90° and 120° of flexion and farthest away at 30° and 150° of extension compared with the other points. Conclusions: To prevent nerve damage during THA, we suggest that the retractor be inserted at the points where the nerves are the farthest away, such as at 30° and 150°. The femoral and sciatic nerves vary in their movements depending on the hip position. Therefore, the safe insertion of a retractor is recommended for hip flexion of the femoral nerve and extension of the sciatic nerve. Additionally, it is important to carefully insert the retractor along the acetabular margin without penetrating the joint capsule. Overall, this study provides valuable insights into the anatomical location and movement of the femoral and sciatic nerves in relation to hip motion and can help inform surgical techniques for safer THA.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3