Affiliation:
1. Orthopaedic Department, Hospital la Paz, Madrid - Spain
Abstract
Seventy cemented cups associated with impacted morsellised allograft in revision surgery in hips with an acetabular bone defect greater than 30% (Paprosky Grades 3A and 3B) were analyzed. The mean follow-up was 6.8 years. One hip showed cup migration and was re-revised; this represents a total cumulative probability of re-revision of the cup of 1.4 ± 2.8%. Radiolucent lines were uncommon: six cups showed radiolucent lines in DeLee and Charnley zone 1, five in zones 1 and 2, one in all three zones, while one hip showed migration. Although the frequent use of a metallic mesh makes graft remodeling difficult to evaluate, six hips showed minor and one major bone resorption. The midterm results with impacted allograft and cemented all-polyethylene cups are favourable in acetabular revision surgery.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献