Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?

Author:

Berliner Zachary P1ORCID,Jawad Muhammad Umar2,Matzko Chelsea3,Cooper H John4,Rodriguez Jose A5,Hepinstall Matthew S6ORCID

Affiliation:

1. Department of Orthopaedic Surgery, Boston University Medical Center, Boston, Massachusetts, USA

2. Department of Orthopaedic Surgery, University of California, Davis, Sacramento, California, USA

3. Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA

4. Department of Orthopaedic Surgery, Columbia University Medical Center, New York, NY, USA

5. Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA

6. Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA

Abstract

Introduction: Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome. Methods: All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database ( n = 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients. Results: Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines ( p < 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines. Discussion: We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3