The Initial Stability of Femoral Impaction Grafting

Author:

Smith E.J.1,Richardson J.B.2,Learmonth I.D.1,Evans G.P.3,Nelson K.3,Lee R.3,Dyson J.3

Affiliation:

1. Department of Orthopaedic Surgery, University of Bristol, Bristol

2. Institute of Orthopaedics, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry

3. AEA Technology, Harwell - UK

Abstract

Aseptic loosening is the major cause of failure in primary total hip replacements. Loss of bone stock occurs in both cementless and cemented implants. Impaction of morsellised allograft represents a major advance in the restoration of bone loss at revision hip surgery. This study was designed to test the early stability of the femoral impaction construct. Polished double tapered stems were inserted into neomedullary canals within impacted allograft in fibreglass femora. Subsidence was measured during cyclical loading. Four methods of impaction grafting were tested: allograft alone; allograft and heparinised blood; allograft/cement/heparinised blood; allograft/cement/clotted blood. Uncemented impaction grafting failed at low loads and few cycles. The cemented technique supported higher loads. Heparinised blood reduced the strength of the composite. Initial stability was achieved with allograft, cement and clotted blood. There is need for caution in the early post-operative period due to the wide variation in initial stability of the allograft composite. The reliability of this technique has been increased by the use of specialised instruments. Experimental studies and clinical experience suggest that this approach to revision surgery is technique dependent.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Impaction femoral allografting at revision hip arthroplasty;The Journal of Bone and Joint Surgery. British volume;2012-01

2. Impaction bone grafting in revision hip surgery: past, present and future;Cell and Tissue Banking;2010-01-15

3. Stability of fused versus nonfused THA Femoral impaction grafts;Journal of Orthopaedic Research;2007-03

4. A Hydroxyapatite Graft Substitute Reduces Subsidence in a Femoral Impaction Grafting Model;Clinical Orthopaedics and Related Research;2007-02

5. Technical factors affecting cup stability in bone impaction grafting;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2007-01-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3