Does-dual mobility still offer improved stability in smaller cup sizes? A computer modelling comparison of stability with 22-mm versus 28-mm inner heads in dual-mobility versus single-bearing constructs

Author:

Atrey Amit1,Navacchia Alessandro2,Ward Sarah E1,Rister David2,Brillantes Jacqueline1,Stavrakis Alexandra3,Khoshbin Amir1

Affiliation:

1. St. Michael’s Hospital, University of Toronto, Toronto, ON, Canada

2. Smith & Nephew Inc, Memphis, TN, USA

3. Department of Orthopaedic Surgery, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, CA, USA

Abstract

Purpose: Dislocation remains 1 of the leading causes of revision after primary total hip arthroplasty (THA) and there is clear evidence the dual-mobility (DM) is used more frequently to minimise this. But in smaller cups, whether the use of DM with smaller 22-mm heads imparts any increased stability compared to standard bearing is unknown; especially when those smaller cups now allow for large single-bearing (SB) heads. Methods: 3 primary cup sizes (48 mm, 50 mm, 52 mm) were chosen a priori for modelling. Head sizes trialled for the standard bearing (SB) constructs group were 28-0 mm, 32-0 mm and 36-0 mm against neutral polyethylene liners. In the modular sub-hemispheric DM constructs the inner head sizes for the DM constructs were altered where appropriate (22-0 mm vs. 28-0 mm). Cup position, stem offset, and stem size were standardised. Results: Both DM constructs outperformed all SB constructs because of a statistically significant jump distance increase ( p < 0.001). However, there was no difference in range of motion (ROM) or jump distances between the 22-mm and 28-mm DM inner heads. The ROM angle before impingement between the DM (with 22-mm or 28-mm heads) and SB (with different head sizes where appropriate) showed no statistically significant difference. However, DM constructs presented significantly larger jump distances than SB constructs for both provocative dislocation tests across all 3 cup sizes. Of interest, for 50-mm and 52-mm cup sizes (for which this particular DM construct design can accommodate both 22-mm and 28-mm inner heads), there were no differences in ROM or jump distance between 22-mm versus 28-mm inner heads. Conclusions: In this computer-modelling study, DM constructs are advantageous over SB constructs for improving jump distances in clinically provocative positions, but not range of motion angles. Inner head diameter of DM has no effect on stability.

Publisher

SAGE Publications

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3