Do trabecular metal and cancellous titanium implants reduce the risk of late haematogenous infection? An experimental study in rabbits

Author:

Komnos George1,Banios Konstantinos1,Kolonia Konstantina2,Poultsides Lazaros A3,Petinaki Efthimia4,Sarrou Styliani4,Zintzaras Elias5,Karachalios Theofilos1

Affiliation:

1. Orthopaedic Department, School of Health Sciences, Faculty of Medicine of University of Thessalia, University General Hospital, Larissa, Greece

2. Anaesthesiology Department, University General Hospital, Larissa, Greece

3. NYU Langone Health, NYU Langone Orthopedic Hospital, New York, USA

4. Microbiology Department, School of Health Sciences, Faculty of Medicine of University of Thessalia, University General Hospital, Larissa, Greece

5. Department of Biostatistics and Clinical Bioinformatics, School of Health Sciences, Faculty of Medicine of University of Thessalia, University General Hospital, Larissa, Greece

Abstract

Aim: This study evaluated the late resistance to haematogenous contamination by microbial pathogens of implants and bone-implant interface and the development of late clinical infection when cementless components with different surface or structural properties are implanted. Material and methods: 50 adult male New Zealand white rabbits were divided into 5 groups of 10 animals each. In Group A smooth titanium, in Group B grit blasted titanium, in Group C HA-coated titanium, in Group D trabecular metal and in group E cancellous titanium rods were implanted in the right proximal tibia. Four weeks later, 1 ml of inoculum of a standardised CA-MRSA strain (3 × 108 cfu/ml) was injected through a femoral artery catheter (groups B, C, D, E) while in group A, 1 ml of sterile saline was injected in a similar way (control group). Subjects were killed 8 weeks after the initial procedure and 3 samples of each tibial specimen were subjected to conventional cultures and PCR studies. Results: The number of the specimens (conventional cultures and PCR studies) contaminated by the standardized pathogen was as follows: Group A: 0/10, Group B: 7/10, Group C: 6/10, Group D; 5/10 and Group E: 5/10. Comparing the number of colony form units isolated from the implant samples, Group B (GB titanium) showed statistically significantly higher values (Mann-Whitney test) compared to Group C ( p = 0.044), Group D ( p = 0.040) and Group E ( p = 0.038). Local active infection was observed in 6 animals: 3 in Group B; 1 in Group C, 1 in Group D, and 1 in Group E. Conclusions: Modern cementless implants (trabecular metal and cancellous titanium) showed a lower risk of implant contamination and late clinical haematogenous infection.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3