Characterisation of microvessel blood velocity and segment length in the brain using multi-diffusion-time diffusion-weighted MRI

Author:

Scott Lauren A12ORCID,Dickie Ben R12,Rawson Shelley D3,Coutts Graham12,Burnett Timothy L3,Allan Stuart M12ORCID,Parker Geoff JM34,Parkes Laura M12ORCID

Affiliation:

1. Division of Neuroscience and Experimental Psychology, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK

2. Geoffrey Jefferson Brain Research Centre, Manchester Academic Health Science Centre, Northern Care Alliance & University of Manchester, Manchester, UK

3. The Henry Royce Institute, Department of Materials, The University of Manchester, Manchester, UK

4. Bioxydyn Limited, Manchester, UK

Abstract

Multi-diffusion-time diffusion-weighted MRI can probe tissue microstructure, but the method has not been widely applied to the microvasculature. At long diffusion-times, blood flow in capillaries is in the diffusive regime, and signal attenuation is dependent on blood velocity ([Formula: see text]) and capillary segment length ([Formula: see text]). It is described by the pseudo-diffusion coefficient ([Formula: see text]) of intravoxel incoherent motion (IVIM). At shorter diffusion-times, blood flow is in the ballistic regime, and signal attenuation depends on [Formula: see text], and not [Formula: see text]. In theory, [Formula: see text] could be estimated using [Formula: see text] and [Formula: see text]. In this study, we compare the accuracy and repeatability of three approaches to estimating [Formula: see text], and therefore [Formula: see text]: the IVIM ballistic model, the velocity autocorrelation model, and the ballistic approximation to the velocity autocorrelation model. Twenty-nine rat datasets from two strains were acquired at 7 T, with [Formula: see text]-values between 0 and 1000 smm−2 and diffusion times between 11.6 and 50 ms. Five rats were scanned twice to assess scan-rescan repeatability. Measurements of [Formula: see text] were validated using corrosion casting and micro-CT imaging. The ballistic approximation of the velocity autocorrelation model had lowest bias relative to corrosion cast estimates of [Formula: see text], and had highest repeatability.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Neurology (clinical),Neurology