Viscoelastic material models for more accurate polyethylene wear estimation

Author:

Alotta Gioacchino1,Barrera Olga23,Pegg Elise C4

Affiliation:

1. Bio/NanoMechanics for Medical Sciences Laboratory, ATeN-Center, Universita’ degli Studi di Palermo, Palermo, Italy

2. School of Engineering, Computing and Mathematics, Oxford Brookes University, Oxford, UK

3. Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK

4. Department of Mechanical Engineering, University of Bath, Bath, UK

Abstract

Wear debris from ultra-high-molecular-weight polyethylene components used for joint replacement prostheses can cause significant clinical complications, and it is essential to be able to predict implant wear accurately in vitro to prevent unsafe implant designs continuing to clinical trials. The established method to predict wear is simulator testing, but the significant equipment costs, experimental time and equipment availability can be prohibitive. It is possible to predict implant wear using finite element methods, though those reported in the literature simplify the material behaviour of polyethylene and typically use linear or elastoplastic material models. Such models cannot represent the creep or viscoelastic material behaviour and may introduce significant error. However, the magnitude of this error and the importance of this simplification have never been determined. This study compares the volume of predicted wear from a standard elastoplastic model, to a fractional viscoelastic material model. Both models have been fitted to the experimental data. Standard tensile tests in accordance with ISO 527-3 and tensile creep recovery tests were performed to experimentally characterise both (a) the elastoplastic parameters and (b) creep and relaxation behaviour of the ultra-high molecular weight polyethylene. Digital image correlation technique was used in order to measure the strain field. The predicted wear with the two material models was compared for a finite element model of a mobile-bearing unicompartmental knee replacement, and wear predictions were made using Archard’s law. The fractional viscoelastic material model predicted almost ten times as much wear compared to the elastoplastic material representation. This work quantifies, for the first time, the error introduced by use of a simplified material model in polyethylene wear predictions, and shows the importance of representing the viscoelastic behaviour of polyethylene for wear predictions.

Funder

Ministero dell’Istruzione, dell’Università e della Ricerca

Publisher

SAGE Publications

Subject

Applied Mathematics,Mechanical Engineering,Mechanics of Materials,Modeling and Simulation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3