The Effect of Three Different Miniaturized Blood Purification Devices on Plasma Cytokine Concentration in an Ex Vivo Model of Endotoxinemia

Author:

Haase M.12,Bellomo R.1,Baldwin I.1,Haase-Fielitz A.12,Storr M.3,Krause B.3,Boyce N.4,Svobodova S.5,Li W.1,Bagshaw S. M.1,Warrillow S.1,Langenberg C.1,Morgera S.6

Affiliation:

1. Intensive Care Research, Austin Health, University of Melbourne - Australia

2. Department of Nephrology and Intensive Care, Chiarité University Medicine, Campus Virchow-Klinikum, Berlin - Germany

3. Gambro Dialysatoren & Co. KG, Hechingen - Germany

4. Australian Red Cross Blood Service, University of Melbourne - Australia

5. Ludwig Institute for Cancer Research, Austin Health, University of Melbourne - Australia

6. Department of Nephrology, Chiarité University Medicine, Campus Mitte, Berlin - Germany

Abstract

Purpose A novel type of adsorptive plasma filtering device (ETX-A) capable of removing endotoxin from blood in a single step has recently been developed using nanotechnology. Methods In a miniaturized, ex vivo model of extracorporeal circuits, we tested the capacity to reduce plasma cytokine concentration of ETX-A filters in comparison to standard high-flux (HF) filters, high cut-off (HCO) filters and a control. Blood from six healthy volunteers was spiked with endotoxin and then circulated through closed (ETX-A, control) or open (HF, HCO) circuits. Blood flow was set at 16 ml/min and filtration flow at 1 ml/min. Samples for measurement of IL-1ra and IL-6 were taken at baseline and at 4 hours. Results Compared to control (703.3 [850.6] pg/mL), in HCO (383.5 [1144.1] pg/mL) and ETX-A (490.1 [683.2] pg/mL) filters, plasma IL-1ra pooled pre- and postfilter concentrations were lower at the end of the experiment (P=0.002; P=0.050, respectively) whereas, in standard HF filters, IL-1ra concentration was higher than control. HCO showed a trend toward a reduced relative increase in IL-6 concentration from commencement to end of experiment compared to control (P=0.07). After pooling end-of-experiment plasma cytokine values of novel blood purification devices, we found HCO + ETX-A superior to H with regard to reduction of IL-1ra (-27.0 [−20.5]% vs. 8.1 [18.9]%; P<01) and IL-6 (-18.0 [38.3]% vs. −1.1 [24.3]%; P=0.050) compared to control. Conclusions HCO and ETX-A appeared to significantly reduce plasma IL-1ra and, when combined, plasma IL-6 concentration as well. It appears desirable to manufacture full-size blood purification devices using this technology and to explore their effect on cytokine removal.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3