The aims of our cross-over randomized study were (1) to assess hemostasis in patients with acute renal failure (ARF) and (2) to determine whether or not the generally recommended heparin rinse of the extracorporeal circuit (ECC) prior to the procedure affects thrombogenicity, complement activation, and leukocyte count in blood during continuous venovenous hemodiafiltration (CVVHDF). Eleven critically ill ARF patients were treated, in random order, using CVVHDF in postdilution setup following ECC rinse with saline (A) with heparin at a concentration of 2,000 IU/L (10 procedures), (B) with heparin at a concentration of 10,000 IU/L (7 procedures), and (C) without heparin (9 procedures). Except for the rinse, anticoagulation therapy did not differ in individual patients during the procedures. Blood was withdrawn before, and at minutes 15, 60, and 360, invariably at diafilter inlet and outlet. Compared with healthy individuals, patients showed lower blood thrombocyte counts (153 vs 233*109/L, p<0.01, arithmetic means, Student's t test), longer aPTT (44 vs 36 s, p<0.05), higher plasma levels of heparin (0.1 vs 0.0 U/mL, p<0.05), D-dimer (1129 vs 36 ng/mL, p<0.001) and beta-thromboglobulin (BTG) (159 vs 37 U/mL, p<0.001) prior to CVVHDF. The comparison of procedures with different rinsing technique did not reveal any significant difference in their effects on blood thrombocyte and leukocyte counts, aPTT, plasma levels of heparin, BTG, thrombin-antithrombin III complexes, D-dimer, or the C5a complement component. Conclusions: (1) Patients indicated for CVVHDF show impaired hemostasis involving thrombocytes, coagulation, and fibrinolysis, (2) no beneficial effect of heparin rinse on CVVHDF ECC thrombogenicity, complement activation or blood leukocyte counts was demonstrated.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3