19 mm Sized Bileaflet Valve Prostheses’ flow Field Investigated by Bidimensional Laser Doppler Anemometry (part I: Velocity Profiles)

Author:

Barbaro V.1,Grigioni M.1,Daniele C.1,D'avenio G.1,Boccanera G.1

Affiliation:

1. Laboratory of Biomedical Engineering, Istituto Superiore di Sanità, Roma - Italy

Abstract

The investigation of the flow field downstream of a cardiac valve prosthesis is a well established task. In particular turbulence generation is of interest if damage to blood costituents is to be assessed. Several prosthetic valve flow studies are available in literature but they generally concern large-sized prostheses. The FDA draft guidance requires the study of the maximum Reynolds number conditions for a cardiac valve model to assess the worst case in turbulence by chosing both the minimum valve diameter and a high cardiac output value as protocol set up. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, the Laboratory of Biomedical Engineering is currently conducting an in-depth study of turbulence generated downstream of bileaflet cardiac valves. Four models of 19 mm sized bileaflet valve prostheses, namely St Jude Medical HP, Edwards Tekna, Sorin Bicarbon, and CarboMedics, were studied in aortic position. The prostheses were selected for the nominal annulus diameter reported by the manufacturers without any assessment of the valve sizing method. The hemodynamic function was investigated using a bidimensional LDA system. Results concern velocity profiles during the peak flow systolic phase, at high cardiac output regime, highlighting the different flow field features downstream of the four small-sized cardiac valves.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Modeling and prediction of flow-induced hemolysis: a review;Biomechanics and Modeling in Mechanobiology;2019-03-07

2. A Mathematical Model of Discharge Coefficient for Prosthetic Valves’ Performance Evaluation;XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016;2016

3. Permeability Prediction of Human Proximal Femoral Trabeculae in the Direction of Superior-to-Fovea Utilizing Directly Measured Microscopic Poroelastic Properties;XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016;2016

4. Changes in Turbulence With Rotation of the Omnicarbon Prosthesis;ASAIO Journal;2007-07

5. Lattice Boltzmann dynamic simulation of a mechanical heart valve device;Mathematics and Computers in Simulation;2007-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3