Combining SPECT Medical Imaging and Computational Fluid Dynamics for Analyzing Blood and Dialysate Flow in Hemodialyzers

Author:

Eloot S.1,D'asseler Y.2,De Bondt P.3,Verdonck P.1

Affiliation:

1. Hydraulics Laboratory, Institute for Biomedical Technology, Ghent University, Gent - Belgium

2. Department of Electronics & Information Systems, Institute for Biomedical Technology, Ghent University, Gent - Belgium

3. Department of Nuclear Medicine, Institute for Biomedical Technology, Ghent University Hospital, Gent - Belgium

Abstract

For a better insight in dialyzer efficiency with respect to local mass transport in a low flux dialyzer (Fresenius F6HPS), blood and dialysate flow distributions were visualized with computational fluid dynamic (CFD) simulations, which were validated with single photon emission computed tomography (SPECT) imaging. To visualize blood-side flow while avoiding transport through the fiber membrane, a bolus of 99m-Technetium labeled MAA (Macro Aggregated Albumin) was injected in the flow using an electronic valve. Water was used to simulate blood, but flow rate was adjusted according to laws of dynamic similarity to account for the viscosity difference (factor 2.75). For the visualization of dialysate flow, a bolus of 99m-Technetium labeled DMSA (Dimercaptosuccinic Acid) was injected, while pressurized air in the blood compartment avoided transmembrane flow. For each test series, 3D acquisitions were made on a two respectively three-headed SPECT camera. By evaluating the images at different time steps, dynamic 3D intensity plots were obtained, which were further used to derive local flow velocities. Additionally, three-dimensional CFD models were developed for simulating the overall blood and dialysate flow, respectively. In both models, the whole fiber compartment was defined as a porous medium with overall axial and radial permeability derived theoretically and from in vitro tests. With the imaging as well as with the computational technique, a homogeneous blood flow distribution was found, while vortices and fluid stagnation were observed in the dialyzer inlet manifold. The non-homogeneous dialysate distribution, as found with SPECT imaging, implies the occurrence of non-efficient sites with respect to mass transfer. The discrepancy between the dialysate results of both techniques indicated that the assumption of a constant fiber bundle permeability in the CFD model was too optimistic. In conclusion, medical imaging techniques like SPECT are very helpful to validate CFD models, which can be further applied for dialyzer design and optimization.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3