Tissue plasminogen activator in left ventricular assist device-related intravascular hemolysis after failed augmented anticoagulation

Author:

Kenneth Sims Robert12,Srour Nina2,El Nihum Lamees I12ORCID,Hannawi Bashar3,Araujo-Gutierrez Raquel2,Cruz-Solbes Ana S4,Trachtenberg Barry H2,Hussain Imad2,Kim Ju H2,Kassi Mahwash2,Graviss Edward A2ORCID,Nguyen Duc T2ORCID,Estep Jerry5,Bhimaraj Arvind2,Guha Ashrith2

Affiliation:

1. Texas A&M College of Medicine, Bryan, TX, USA

2. DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, TX, USA

3. Henry Ford Hospital, Detroit, MI, USA

4. Yale School of Medicine, New Haven, CT, USA

5. Cleveland Clinic, Cleveland, OH, USA

Abstract

Objectives: We sought to examine the efficacy and safety of adding fibrinogen-guided low-dose multi-day Alteplase™ tissue plasminogen activator (tPA) in the management of intravascular hemolysis (IVH) in patients with the HeartMate II (HM-II) continuous flow (CF) left ventricular assist device (LVAD) who failed to achieve IVH resolution with conventional augmented anticoagulation (AAC). Background: IVH in patients with LVAD is often treated with AAC, failing which pump exchange is considered. We hypothesized that a trial of low-dose tPA after failed AAC therapy could resolve IVH and prevent pump exchange in some patients. Methods: We performed a retrospective study of 31 HM-II CF LVAD patients admitted to our center from January 2015 to January 2020 for IVH management who received tPA following failed AAC. Primary 6-month outcomes included successful IVH resolution, unsuccessful IVH resolution requiring pump exchange, gastrointestinal bleeding, ischemic and hemorrhagic cerebrovascular accident (CVA), and death. Results: Thirty-one patients with IVH were treated with tPA following failed AAC. Successful resolution of IVH occurred in 22/31 (71%) patients. Pump exchange occurred in 9/31 (29%) patients. Gastrointestinal bleeding occurred in 7/31 (22.6%) patients. Ischemic CVA occurred in 6/31 (19.4%) patients. Conclusions: Management of IVH with administration of low-dose tPA after failed AAC is feasible and may prevent pump exchange in some patients.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术