Pulmonary artery pressure may be a predictor of closed aortic valve in patients managed by venoarterial extracorporeal membrane oxygenation

Author:

Yamaguchi Shogo1,Sawamura Akinori2ORCID,Okumura Takahiro1,Kato Hiroo1,Oishi Hideo1,Arao Yoshihito1,Haga Tomoaki1,Kuwayama Tasuku1,Yokoi Tsuyoshi1,Hiraiwa Hiroaki1,Kondo Toru1,Morimoto Ryota1,Murohara Toyoaki1

Affiliation:

1. Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan

2. Ichinomiya Municipal Hospital, Ichinomiya, Japan

Abstract

In the management of venoarterial extracorporeal membrane oxygenation, some patients present persistently closed aortic valve. However, little is known about the variables that contribute to persistently closed aortic valve. We investigated the factors that could predict persistently closed aortic valve at the time of venoarterial extracorporeal membrane oxygenation initiation. We investigated 17 patients who presented closed aortic valve immediately after the introduction of venoarterial extracorporeal membrane oxygenation. Patients who presented closed aortic valve 24 h after introduction of venoarterial extracorporeal membrane oxygenation were defined as the Closed-AV group (n = 8), while those whose aortic valve remained opened after 24 h were defined as the Open-AV group (n = 9). All patients were managed by concomitant use of intra-aortic balloon pumping. At baseline, there were no significant differences between mean arterial blood pressure, central venous pressure, and left ventricular ejection fraction. However, Closed-AV group had significantly lower mean pulmonary artery pressure and pulmonary artery pulse pressure compared to those of Open-AV group (mean pulmonary artery pressure: 15 ± 6 mmHg vs 25 ± 8 mmHg, p = 0.01; pulmonary artery pulse pressure: 3 ± 2 mmHg vs 8 ± 3 mmHg, p < 0.01). Logistic regression analyses revealed that the lower mean pulmonary artery pressure and pulmonary artery pulse pressure had the predictive value of closed aortic valve within 24 h after venoarterial extracorporeal membrane oxygenation initiation (mean pulmonary artery pressure: odds ratio = 0.78, 95% confidence interval = 0.58–0.95, p < 0.01; pulmonary artery pulse pressure: odds ratio = 0.18, 95% confidence interval = 0.01–0.61, p < 0.01). Lower mean pulmonary artery pressure and pulmonary artery pulse pressure values could predict persistent closed aortic valve 24 h after venoarterial extracorporeal membrane oxygenation initiation. Left ventricular preload derived from right heart function may have a major impact on aortic valve status.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3