Prevention of Hypovolemia-Induced Hypotension during Hemodialysis by Means of an Optical Reflection Method

Author:

De Vries J.P.P.M.1,Donker A.J.M.2,De Vries P.M.J.M.2

Affiliation:

1. Medical Physics, Free University Hospital, Amsterdam, - The Netherlands

2. Departments of Internal Medicine, Amsterdam, - The Netherlands

Abstract

In this study protocol we evaluate the clinical value of the continuous monitoring of blood volume (BV) during hemodialysis (HD) by means of an optical reflection method. In the course of a dialysis session the ratio between the ultrafiltration (UF) rate and the patient's refill capacity determines the extent of decrease of BV. A steep fall of BV and, moreover, a remaining absolute BV too low, cause the greater part of hemodialysis-induced complaints. During 23 standard HD sessions BV was monitored by means of the optical method. Nine of the sessions were complicated by hypotension (group H). Comparison of the mean BV graphs of group H with the graphs of non-complicated sessions (non-H) produces several differences. Most important is the fact that BV is better preserved in group non-H, a difference which is already significant during the first ninety minutes of dialysis. By making use of the shape of the monitored BV graph an HD patient, in that way, might be recognized as hypotension-prone during the first third of a dialysis session. To prevent the occurrence of hypovolemia-induced hypotension two strategies can be followed. First, the decrease of BV of a patient prone to hypotension can be triggered to the mean BV decrease according to the BV graph of the non-H group. This can be achieved by interventional methods, e.g. temporary lowering of the UF rate. However, for this intervention the development of a closed-loop circuit is required. Another possibility is to measure a patient's maximal refill capacity each hour of hemodialysis by taking advantage of the displayed BV graph. When the UF rate during ensuing sessions is kept in rate with the measured maximum values the occurrence of hypovolemia-induced hypotension will be minimized.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com