Ozonation of Blood during Extracorporeal Circulation. I. Rationale, Methodology and Preliminary Studies

Author:

Bocci V.1,Di Paolo N.2,Garosi G.2,Aldinucci C.1,Borrelli E.3,Valacchi G.1,Cappelli F.2,Guerri L.4,Gavioli G.5,Corradeschi F.1,Rossi R.6,Giannerini F.6,Di Simplicio P.6

Affiliation:

1. Institute of General Physiology, University of Siena, Siena

2. Dialysis and Nephrology Unit, Azienda Ospedaliera Senese, Siena

3. Institute of Thoracic and Cardiovascular Surgery, University of Siena, Siena

4. Veterinary Clinic, University of Siena, Siena

5. Braun Carex, Mirandola, Modena

6. Institute for Mental and Nervous Diseases, Pharmacology Section, University of Siena, Siena - Italy

Abstract

We investigated whether exposure of blood ex-vivo to oxygen-ozone (O2-O3) through a gas exchanger is feasible and practical. We first evaluated the classical dialysis-type technique but we soon realized that semipermeable membranes are unsuitable because they are hydrophilic and vulnerable to O3. We therefore adopted a system with hydrophobic O3-resistant hollow fibers enclosed in a polycarbonate housing with a membrane area of about 0.5 m2. First we tested the system with normal saline, determining the production of hydrogen peroxide (H2O2) at O3 concentrations from 5 to 40 μg/ml. We then evaluated critical parameters by circulating swine blood in vitro; this revealed that heparin is not an ideal anticoagulant for this system. Finally, we performed several experiments in sheep and defined optimal anticoagulant dose (sodium citrate, ACD), priming solution, volume of blood flow per min, volume and concentration of O2-O3 mixture flowing counter-current with respect to blood and the time necessary for perfusion in vivo. The biochemical parameters showed that an O3 concentration as low as 10 μg/ml is effective; this means that gas exchange and O3 reactivity are rapid and capable of inducing biological effects. The sheep showed no adverse effects even after 50 min of extracorporeal circulation at higher O3 concentrations (20 to 40 μg/ml) but the exchanger became less effective (low pO2 values) due to progressive clogging with cells.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Reference15 articles.

1. ViebahnR. The use of ozone in medicine. Heidelberg: Karl F. Haug Publishers, 1994; 1–178.

2. Is Ozone Therapy Therapeutic?

3. Studies on the biological effects of ozone: 8. Effects on the total antioxidant status and on interleukin-8 production

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3