Sound analysis of the magnetically levitated left ventricular assist device HeartMate 3™

Author:

Sundbom Per12ORCID,Roth Michael3,Granfeldt Hans24,Karlsson Daniel M5,Ahn Henrik24,Gustafsson Fredrik3,Dellgren Göran67,Hubbert Laila78

Affiliation:

1. Department of Medicine and Geriatrics, Höglandet Hospital, Eksjö, Sweden

2. Department of Medical and Health Sciences, Linköping University, Linköping, Sweden

3. Department of Electrical Engineering, Linköping University, Linköping, Sweden

4. Department of Thoracic and Vascular Surgery, Linköping University Hospital, Linköping, Sweden

5. Department of Biomedical Engineering, Linköping University, Linköping, Sweden

6. Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden

7. Transplant Institute, Sahlgrenska University Hospital, Gothenburg, Sweden

8. Departments of Cardiology and Medical and Health Sciences, Linköping University, Norrköping, Sweden

Abstract

Introduction: The HeartMate 3 has shown lower rates of adverse events compared to previous devices due to the design and absence of mechanical bearings. For previous devices, sound analysis emerged as a way to assess pump function. The aims of this study were to determine if sound analysis can be applied to the HeartMate 3 in vivo and in vitro and to evaluate an electronic stethoscope. Method: Sound recordings were performed with microphones and clinical accessible electronic stethoscope. The recordings were studied in both the time and the frequency domains. Recordings from four patients were performed to determine if in vivo and in vitro recordings are comparable. Results: The results show that it is possible to detect sound from HeartMate 3 and the sound spectrum is clear. Pump frequency and frequency of the pulsatile mode are easily determined. Frequency spectra from in vitro and in vivo recordings have the same pattern, and the major proportion (96.7%) of signal power is located at the pump speed frequency ±40 Hz. The recordings from the patients show low inter-individual differences except from location of peaks originating from pump speed and harmonics. Electronic stethoscopes could be used for sound recordings, but the dedicated equipment showed a clearer sound spectrum. Discussion: The results show that acoustic analysis can also be performed with the HeartMate 3 and that in vivo and in vitro sound spectrum is similar. The frequency spectra are different from previous devices, and methods for assessing pump function or thrombosis need further evaluation.

Funder

Grants from the County Council of Ostergotland

Grants from Linkoping University foundations

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering