Can the Artificial Heart Make the Circulation Become Fractal?

Author:

Yambe T.1,Nanka S.1,Naganuma S.1,Kobayashi S.1,Akiho H.1,Kakinuma Y.1,Ohsawa N.1,Nitta S.1,Fukuju T.2,Miura M.2,Uchida N.2,Tabayashi K.2,Tanaka A.3,Yoshizumi N.3,Abe K.3,Takayasu M.4,Takayasu H.5,Yoshizawa M.5,Takeda H.6

Affiliation:

1. Department of Medical Engineering and Cardiology, Division of Organ Pathophysiology, Institute of Development, Aging and Cancer, Tohoku University, Sendai

2. Department of Thoracic and Cardiovascular Surgery, Tohoku University School of Medicine, Sendai

3. Department of Electrical Engineering, Faculty of Engineering, Tohoku University, Sendai

4. Research Institute for Fracture Technology, Faculty of Engineering, Tohoku University, Sendai

5. Graduate School of Information Sciences, Tohoku University, Sendai

6. Faculty of Engineering, Tohoku-gakuin University, Sendai - Japan

Abstract

In order to analyze the hemodynamic parameters in prosthetic circulation as an entity and not as decomposed parts, non linear mathematical analyzing techniques, including the fractal dimension analyzing theory, were utilized. Two pneumatically actuated ventricular assist devices were implanted, as biventricular bypasses (BVB), in chronic animal experiments, using four healthy adult goats. For the comparison between the natural and prosthetic circulation in the same animals, the BVB type complete prosthetic circulation model with ventricular fibrillation, was adopted. All hemodynamic parameters with natural and prosthetic circulation were recorded under awake conditions, and calculated with a personal computer system. Using the non-linear mathematical technique, the arterial blood pressure waveform was embedded into the return map as the beat-to-beat time series data and fractal dimension analysis were performed to analyze the reconstructed attractor. By the use of the Box counting method, fractal dimension analysis of the hemodynamics was performed. Return map of the hemodynamics during natural and artificial circulation showed fractal characteristics, and fractal dimension analysis of the arterial blood pressure revealed the fact that lower dimensional fractal dynamics were evident during prosthetic circulation. Fractal time series data is suggested to have robustness and error resistance, thus our results suggest that the circulatory regulatory system with an artificial heart may have these desired characteristics.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3