PMEA Polymer-Coated PVC Tubing Maintains Anti-Thrombogenic Properties during in vitro Whole Blood Circulation

Author:

Yoshizaki T.1,Tabuchi N.1,Van Oeveren W.2,Shibamiya A.3,Koyama T.3,Sunamori M.1

Affiliation:

1. Department of Cardio-Thoracic Surgery, Graduate School of Medicine, Tokyo - Japan

2. Department of Biomedical Engineering, University of Groningen - The Netherlands

3. Graduate School of Health Sciences, Tokyo Medical and Dental University, Tokyo - Japan

Abstract

Poly(2-methoxyethylacrylate) (PMEA) is a new coating material that appears to reduce protein and platelet adsorption. However, the exact performance of PMEA coated circuit remains to be revealed in well-controlled experiments. Therefore, we compared its hemocompatibility with covalent-bound heparin-, and non-coated circuits during 6 hours of in vitro circulation, using donor blood from six volunteers. In our model, simple tubing circuits containing one-way ball valve were placed on the rotary table, which moved alternatively to generate pulsatile recirculation of heparinized human blood inside the tubing. Using this model, we expected fine assessment of the material surface, because we could reduce blood damage by avoiding air and a blood pump. Moreover, the small capacity of circuit allowed us to compare three kinds of circuits using a single unit of donor blood, eliminating effects by possible variations between blood donors. The anti-thrombin capacity of the PMEA-coated circuits was maintained even after six hours blood circulation, whereas surface thrombin generation increased markedly after use in non-coated circuits (P<0.05). Deposition of fibrin onto PMEA circuits was reduced more than 30% compared with heparin and non-coated circuits (P<0.05). However, the increase of plasma Factor XIIa was similar in all circuits. Increase of CD11b expression on circulating leukocytes and of plasma C3a was ameliorated in the heparin- and PMEA-coated circuits (P<0.05). PMEA-coated circuits appear to maintain their anti-thrombogenicity during use, otherwise PMEA-coated and heparin-coated circuits showed a similar character in hemocompatibility. This long-standing anti-thrombogenicity might be attributable to less adsorption of activated blood components onto the surface.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3