Management of Fluid Balance in CRRT: A Technical Approach

Author:

Ronco C.1,Ricci Z.2,Bellomo R.3,Baldwin I.3,Kellum J.4

Affiliation:

1. Department of Nephrology, St. Bortolo Hospital, Vicenza - Italy

2. Department of Intensive Care, Policlinico Umberto I°, Rome - Italy

3. Department of Intensive Care, Austin Hospital, Melbourne - Australia

4. Department of Intensive Care, University of Pittsburgh, Pittsburgh - USA

Abstract

Background The possibility of making fluid balance errors during continuous renal replacement therapy has been identified since the beginning of this modality of treatment. The advent of automated machines has partially overcome this problem. Nevertheless, there are conditions and operation modes in which the potential for fluid balance errors is still present. Objective To analyse fluid balance management in CRRT therapies across a range of currently marketed machine. Methods The tests were conducted in vitro, utilizing saline solution for the blood circuit and regular dialysate/reinfusate for the dialysate/reinfusion circuit. The methodology used was based on the voluntary creation of a fluid balance error by altering the correct flow in the circuit of the different machines. Subsequently, the time for alarm occurrence and the threshold value for fluid balance error was evaluated. The alarm was overridden and the overall fluid error allowed by the machine was evaluated. Each machine was tested in conditions of different dialysate/filtrate flow rates and in different simulated treatment modalities. Results Fluid balance errors can be easily avoided not only by a correct and careful adherence to the protocols of use of the current CRRT machines, but also by the compliance to prescriptions and programmed controls during therapy. Most importantly, if an alarm appears on the machine, one can try to override it without major problems; major problems may occur when multiple override commands are operated without identifying the problem and solving it adequately. Conclusion Machines seem to be designed with adequate safety features and accurate alarm systems. However, features and alarms can be manipulated by operators creating the opportunity for serious error. Physicians and nurses involved in prescription and delivery of CRRT should have precise protocols and defined procedures in relation to machine alarms to prevent major clinical problems.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3