Tissue-Engineered Heart Valve Leaflets: An Animal Study

Author:

Kim W.G.1,Cho S.K.1,Kang M-C.1,Lee T-Y.1,Park J.K.1

Affiliation:

1. Department of Thoracic and Cardiovascular Surgery and Heart Research Institute, Seoul National University College of Medicine and Clinical Research Institute, Seoul National University Hospital, Seoul - Korea

Abstract

Background Tissue-engineered heart valve leaflets are a promising way to overcome the inherent limitations of current prosthetic valves. The aim of this study was to compare the biological responses of an autologous cell seeded scaffold and an acellular scaffold implanted in the pulmonary valve leaflet in the same animal. Methods Myofibroblasts and endothelial cells were isolated and cultured from an ovine artery. A synthetic biodegradable scaffold consisting of polyglycolic acid and polylactic acid was initially seeded with the myofibroblasts, then coated with endothelial cells. Cells were seeded using a medium containing collagen and cultured. A tissue-engineered construct and a plain scaffold were implanted as double pulmonary valve leaflet replacement in the same animal in an ovine model (n=3). Additionally, the tissue-engineered construct (n=2) and the plain scaffold (n=2) were implanted as single valve leaflet replacements for long-term analysis. After sacrifice, the implanted valve leaflet tissues were retrieved, analyzed visually and using light microscopy. Results Three animals that underwent replacement of two valve leaflets with a tissue-engineered construct and a plain scaffold, survived only a short-time (12, 24, 36 hours). The death was attributed to heart failure caused by severe pulmonary insufficiency. Animals that underwent single valve leaflet replacement survived longer and were electively sacrificed at 6 and 9 weeks after operation. The analysis of the leaflets from the short-term survivors showed that the tissue-engineered constructs contained less fibrins and protein exudates than the plain scaffold. In contrast, leaflets obtained from animals surviving 6 and 9 weeks showed similar well organized granulation tissues in the tissue-engineered constructs and the plain scaffolds. Conclusion This animal experiment demonstrates that in the early phase of implantation, the tissue-engineered construct shows a better biological response in terms of antithrombogenicity than the plain scaffold, although both of them have similar results in the later reparative phase.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3