Abstract

A number of different blood-processing methods can be used at the end of cardiopulmonary bypass (CPB) to improve the quality of autologous blood. They include centrifugation, hemofiltration and cell-washing. They differ in processing time required, cost of disposables and the quality of the processed autologous blood product. The newly developed continuous auto-transfusion system (CATS: Fresenius AG, Bad Homburg) uses a continuous cell-washing method. In a prospective study, the oxygenator blood of 10 patients was processed at the end of cardiac surgery with CATS and the quality of autologous blood before and after processing was compared. The processing volumes and the time required were recorded. The concentrations and elimination rates of blood parameters and waste products such as activated coagulation and complement products were measured. At the end of CPB a mean volume of 1,010 ± 174 ml diluted oxygenator blood was processed and concentrated to 310 ± 88 ml in 11.0 ± 2.2 mins. Cellular elements such as erythrocytes and leucocytes were mostly retained and their concentration showed a significant increase after processing (250% and 210% respectively; p < 0.01). Thus, the blood processing with CATS resulted in an excellent hemoconcentration (hematocrit 62 ± 3 vs. 24 ± 4% before processing) with a consistent reproducibility. On the other hand, the CATS concentrate showed a significant loss of autologous plasma proteins. Likewise, all water soluble elements such as waste products are significantly lower in concentration after processing and, if calculated by quantity, they show a high elimination rate (> 93%). In conclusion, the continuous autologous transfusion system permits an automated, rapid and continuous processing of autologous blood yielding a standardised high quality erythrocyte concentrate.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3