PPS-PEG Surface Coating to Reduce Thrombogenicity of Small Diameter ePTFE Vascular Grafts

Author:

Karrer L.1,Duwe J.2,Zisch A.H.34,Khabiri E.1,Cikirikcioglu M.1,Napoli A.3,Goessl A.3,Schaffner T.2,Hess O.M.2,Carrel T.2,Kalangos A.1,Hubbell J.A.3,Walpoth B.H.1

Affiliation:

1. Department of Cardiovascular Surgery, University Hospital, Geneva - Switzerland

2. Swiss Cardiovascular Centre, University Hospital, Berne - Switzerland

3. Institute for Biomedical Engineering, ETH and University of Zurich, Zurich - Switzerland

4. Department of Obstetrics, University Hospital, Zurich - Switzerland

Abstract

Aims Patency failure of small vascular synthetic grafts is still a major problem for coronary and peripheral revascularization. Thus, three new surface coatings of small synthetic grafts were tested in an acute pig model to evaluate their thrombogenicity (extracorporeal arterio-venous shunt) and in a chronic rat model to evaluate the tissue reaction they induced (subcutaneous implantation). Methods In five domestic pigs (25–30 kg) an extracorporeal femoro-femoral arterio-venous shunt model was used. The study protocol included first a non-heparinized perfusion sequence followed by graft perfusion after 10,000 UI iv heparin. Grafts were perfused for 3 and 9 minutes. The following coatings were tested on ePTFE grafts: poly-propylene sulphide (PPS) – poly-ethylene glycol (PEG) (wet and dry applications) as well as carbon. Two sets of control were used, one dry and one wet (vehicle only). After perfusion grafts were examined by scanning electron microscopy for semiquantitative assessment (score 0–3) of cellular and microthrombi deposition. To assess tissue compatibility, pieces of each material were implanted subcutaneously in 16 Wistar rats. At 2, 4, 8, 12 weeks four animals each were sacrificed for semi-quantitative (score 0–3) histologic evaluation of tissue reaction. Results In the pig model, cellular deposition and microthrombi formation increased over time. In non-heparinized animals, the coatings did not improve the surface characteristics, since they did not prevent microthrombi formation and cellular deposition. In heparinized animals, thrombogenicity was lowest in coated grafts, especially in PPS–PEG dry (P&0.05), and highest in controls. Cell deposition was lowest in PPS–PEG dry, but this difference was not statistically significant vs. controls. In the rat model, no significant differences of the tissue reaction could be shown between materials. Conclusion While all coatings failed to add any benefit for lowering tissue reaction, surface coating with PPS–PEG (dry application) reduced thrombogenicity significantly (in heparinized animals) and thus appears to be promising for improving graft patency of small synthetic vascular prostheses.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3