Affiliation:
1. Department of Cardiovascular Surgery, University Hospital, Geneva - Switzerland
2. Swiss Cardiovascular Centre, University Hospital, Berne - Switzerland
3. Institute for Biomedical Engineering, ETH and University of Zurich, Zurich - Switzerland
4. Department of Obstetrics, University Hospital, Zurich - Switzerland
Abstract
Aims Patency failure of small vascular synthetic grafts is still a major problem for coronary and peripheral revascularization. Thus, three new surface coatings of small synthetic grafts were tested in an acute pig model to evaluate their thrombogenicity (extracorporeal arterio-venous shunt) and in a chronic rat model to evaluate the tissue reaction they induced (subcutaneous implantation). Methods In five domestic pigs (25–30 kg) an extracorporeal femoro-femoral arterio-venous shunt model was used. The study protocol included first a non-heparinized perfusion sequence followed by graft perfusion after 10,000 UI iv heparin. Grafts were perfused for 3 and 9 minutes. The following coatings were tested on ePTFE grafts: poly-propylene sulphide (PPS) – poly-ethylene glycol (PEG) (wet and dry applications) as well as carbon. Two sets of control were used, one dry and one wet (vehicle only). After perfusion grafts were examined by scanning electron microscopy for semiquantitative assessment (score 0–3) of cellular and microthrombi deposition. To assess tissue compatibility, pieces of each material were implanted subcutaneously in 16 Wistar rats. At 2, 4, 8, 12 weeks four animals each were sacrificed for semi-quantitative (score 0–3) histologic evaluation of tissue reaction. Results In the pig model, cellular deposition and microthrombi formation increased over time. In non-heparinized animals, the coatings did not improve the surface characteristics, since they did not prevent microthrombi formation and cellular deposition. In heparinized animals, thrombogenicity was lowest in coated grafts, especially in PPS–PEG dry (P&0.05), and highest in controls. Cell deposition was lowest in PPS–PEG dry, but this difference was not statistically significant vs. controls. In the rat model, no significant differences of the tissue reaction could be shown between materials. Conclusion While all coatings failed to add any benefit for lowering tissue reaction, surface coating with PPS–PEG (dry application) reduced thrombogenicity significantly (in heparinized animals) and thus appears to be promising for improving graft patency of small synthetic vascular prostheses.
Subject
Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献