Confirmation of High Cytokine Clearance by Hemofiltration with a Cellulose Triacetate Membrane with Large Pores: An in vivo Study

Author:

Delanaye P.1,Lambermont B.23,Dogné J.-M.34,Dubois B.1,Ghuysen A.23,Janssen N.5,Desaive T.3,Kolh P.35,D'Orio V.23,Krzesinski J.-M.1

Affiliation:

1. Department of Nephrology, University of Liege, Liege - Belgium

2. Department of Medicine, University of Liege, Liege - Belgium

3. Hemodynamic Research Laboratory, HemoLiege, University of Liege, Liege - Belgium

4. Department of Pharmacy, University of Namur, Namur - Belgium

5. Department of Surgery, University of Liege, Liege - Belgium

Abstract

Objective To confirm in vivo the hypothesis that hemofiltration with a large pore membrane can achieve significant cytokine clearance. Method We used a well-known animal model of endotoxinic shock (0.5 mg/kg of lipopolysaccharide from Escherichia Coli over a period of 30 mins). Six pigs were hemofiltrated for 3 hours with a large pore membrane (78 Å pore, 80 kDa cut off) (Sureflux FH 70, Nipro, Osaka, Japan). The ultrafiltration rate was 45 ml/kg/min. Samples were taken from arterial, venous line and in the ultrafiltrate at T120 and T240. We measured concentrations of interleukin 6, interleukin 10 and albumin. Results At T120 and T240, the IL-6 clearances were 22 ± 7 and 15 ± 3 ml/min, respectively. The IL-6 sieving coefficients were 0.97 and 0.7 at T120 and T240, respectively. At T120 and T240, the IL-10 clearances were 14 ± 4 and 10 ± 7 ml/min, respectively. The sieving coefficients were 0.63 and 0.45 at T120 and T240, respectively. The concentrations of IL-6 and IL-10 were the same at T0 and T240. At T60 and T240, the plasmatic albumin concentrations were 24 ± 4 g/L and 23 ± 4 g/L, respectively (p = 0.13). Conclusions In this animal model of endotoxinic shock, we confirm the high cytokine clearance observed when hemofiltration is applied to a large pore membrane. The loss of albumin seems negligible. The impact of such clearances on hemodynamic stability and survival remains to be proved.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. High Cutoff Membranes for Mediators Removal;Critical Care Nephrology;2019

2. Bio-Based Cellulose Acetate Films Reinforced with Lignin and Glycerol;International Journal of Molecular Sciences;2018-04-10

3. Efficacy of hemofiltration with PEPA membrane for IL-6 removal in a rat sepsis model;Journal of Artificial Organs;2017-09-11

4. Medium Cut-Off Membranes - Closer to the Natural Kidney Removal Function;The International Journal of Artificial Organs;2017-05-26

5. 4.11 Progress in the Development of Membranes for Kidney-Replacement Therapy;Comprehensive Membrane Science and Engineering;2017