Leptin and β2-Microglobulin Kinetics with Three Different Dialysis Modalities

Author:

Mandolfo S.1,Borlandelli S.1,Imbasciati E.1

Affiliation:

1. Renal Unit, Ospedale Maggiore, Lodi - Italy

Abstract

Background Leptin is a protein produced by fat cells and involved in body weight regulation. In patients with normal kidney function, leptin has been considered an independent predictor of cardiovascular events. In uremic patients, leptin in plasma serum was assumed to be associated with malnutrition, inflammation and atherosclerosis. Because of its molecular weight and characteristics, leptin can be considered as a protein-bound uremic retention solute. Some authors have reported the possibility of decreasing the serum leptin concentration with high flux membranes, but limited data are available on the elimination with medium-flux membranes or alternative dialysis strategies such as hemodiafiltration. Methods We evaluated the kinetics of leptin and β2m in a study of 18 chronic hemodialysis patients using low-flux, medium-flux and high-flux biocompatible membranes, the last one used in hemodiafiltration (HDF). Blood samples for leptin and β2m were collected pre- and post-treatment and 30 minutes after the end of treatment, over a 1-week period that included 3 dialysis sessions. Clearances of leptin and β2m across the dialyzer were also determined directly from the arterial and venous blood concentrations 60 and 210 minutes after starting dialysis. Results At baseline, all groups showed similar leptin (18.8±4.4 ng/mL) and β2m concentrations (29.2±7.1 ng/mL). After a single dialysis session, a reduction of both solutes was observed with HDF (39.8±1.9%, 78.1±4.9) and medium flux membranes (18.2±0.9%, 52.2±1.7%), whereas the concentrations remained unchanged with the low-flux membranes. After one-week period, a trend of reduction of plasma pre dialysis leptin and β2m were observed with HDF and medium flux membranes. At 60 minutes, HDF showed the best instantaneous clearance across the filter for leptin (56.2±10.1 ml/min) and β2m (75.3±4.4 ml/min). The magnitude of post dialysis rebound of leptin at 30 min was variable and strongly correlated with the instantaneous clearance of the solute (r2= 0.88). Conclusions Leptin serum concentration can be influenced by dialysis modalities and membrane permeability; data on rebound suggest a multicompartimental kinetic of leptin similar to β2m. Leptin removal, as measured by the reduction rate, can be considered as an index of dialysis efficiency for protein-bound uremic retention solutes.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3