Variation in Artificial Heart Acceleration and Sound Production with Prosthetic Valve Selection in vitro

Author:

Pantalos G.M.1,Kim C.H.1,Flatau A.2

Affiliation:

1. University of Utah, Artificial Heart Research Laboratory, Salt Lake City, Utah - USA

2. Department of Aerospace Engineering, Engineering Mechanics/Biomedical Engineering, Iowa State University, Ames, lowa - USA

Abstract

In an attempt to explore methods to reduce total artificial heart (TAH) acceleration and sound production, in vitro measurements of TAH acceleration and sound were made when using a variety of prosthetic valves in a test ventricle. A miniature, uniaxial, high fidelity accelerometer was glued to the housing of a UTAH-100 left ventricle adjacent to the inflow and outflow ports and parallel to the axis of diaphragm excursion. A miniature, high fidelity contact microphone was glued to the opposite side of the ventricular housing between the inflow and outflow ports. Data was collected over a range of heart rates, ventricular filling volumes and control modes while using tilting disc valves (TDV) and polymer trileaflet valves (PTV). For both valve types, the peak systolic acceleration impulse was lower (≈ 50%) when the ventricle was fully rather than partially filled and the peak diastolic acceleration impulse was lower (≈ 50%) when the ventricle was fully rather than partially ejected. The magnitude of the acceleration with PTVs was ≈ 20x less than the TDVs (0.5 to 2.2 g vs. 10 to 49g). The magnitude of the sound production was also considerably less with the PTVs (28 to 49 db vs. 50 to 64 db). Diastolic acceleration and sound production was approximately twice the systolic value for the TDVs; the reserse was true for PTV sound production. These data demonstrate the substantial reduction in TAH impulse acceleration and sound production by selecting PTVs over TDSs. With PTVs, the TAH impulse acceleration is the same as the natural heart. Consequently, this ability to lower TAH acceleration and sound production to the level of the natural heart may lead to a reduction in component wear, patient discomfort and other undesirable consequences of TAH implantation.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3