Effects of Novel Manufacturing Technology on Blood and Dialysate Flow Distribution in a New Low Flux “α Polysulfone” Hemodialyzer

Author:

Gastaldon F.1,Brendolan A.1,Crepaldi C.1,Frisone P.1,Zamboni S.1,D'Intini V.1,Poulin S.1,Hector R.2,Granziero A.3,Martins K.4,Gellert R.2,Inguaggiato P.1,Ronco C.1

Affiliation:

1. Department of Nephrology, St. Bortolo Hospital, Vicenza - Italy

2. B.Braun Medizintechnologie, Melsungen - Germany

3. Department of Radiology, St. Bortolo Hospital, Vicenza - Italy

4. Saxonia Medical, Radeberg - Germany

Abstract

The main target for low flux hemodialyzers is an efficient low molecular weight solutes clearance. Such efficiency is largely dependent on the optimization of diffusion between blood and dialysis solution. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. Thus optimized flow distribution both in the blood and dialysate compartment becomes quintessential for the maximal efficiency of the diffusion process within the hemodialyzer. The present paper describes the distribution of the blood and dialysate flows in a new low flux polysulfone hollow fiber hemodialyzer characterized by a specific undulation of the fibers and a new cutting technology of the fibers for an improved micro-flow condition in the blood compartment headers. Twelve Diacap α Polysulfone LO PS 15 (1.5 sqm) (B.Braun Medizintechnologie, Melsungen Germany) were employed for the study. Six were analyzed in vitro and six were studied in vivo. Blood flow distribution was studied in vitro by dye injection in the blood compartment during experimental extracorporeal circulation utilizing human blood with hematocrit adjusted at 33%. Sequential images were obtained with a helical scanner in a fixed longitudinal section of the dialyzer 1 cm thick. Average and regional blood flow velocities were measured utilizing the reconstructed imaging sequence. The method allowed the calculation of single fiber blood flow (SF Qb) and the mass transfer zone (MTR) definition in digitally subtracted images. The patterns 20–10 and 40–30 were utilized. The same technology was used to evaluate flow distribution in the dialysate compartment after dye injection in the Hansen's connector. Regional dialysate flow was calculated in central and peripheral sample areas of 1 cm2. Six in vivo hemodialysis treatments on patients with end stage renal disease were performed at three different blood flow rates (250–350 and 450 ml/min) in order to measure urea, creatinine and phosphate clearance. Macroscopic and densitometrical analysis revealed that flow distribution was homogeneous in the blood compartment while in the dialysate compartment a slight difference between the peripheral and central regions in terms of flow velocity was observed. This however was not generating channeling phenomena. Urea creatinine and phosphate clearances were remarkably high and so were the Kt/V observed in all sessions, especially in relation to the studied blood flows. In conclusion, a significant blood to dialysate flow match with optimized countercurrent flow condition was observed in the studied hollow fiber hemodialyzers. Such optimization might be due both to the improved dialyzer design at the level of the blood header and to the specific fiber undulation that prevents dialysate channeling.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3