Long-Term Safety and Efficacy of Programmable Implantable Insulin Delivery Systems

Author:

Olsen C.L.1,Liu G.1,Iravani M.1,Nguyen S.1,Khourdadjian K.1,Turner D.S.1,Waxman K.1,Selam J-L.1,Charles M.A.1

Affiliation:

1. Diabetes Research Program, Department of Medicine University of California, Irvine, California - USA

Abstract

Objectives Since only short-term studies of continuous intraperitoneal insulin infusion (CIPII) therapy using implantable programmable insulin delivery systems have been performed to show this method of diabetes therapy to be safe and efficacious, we have performed long-term studies to assess its safety and efficacy. Research design and methods For 78 patient-years of follow-up, we have longitudinally studied the incidence of diabetic ketoacidosis and severe hypoglycemia in 25 type 1 diabetic patients treated with CIPII. We also compared, cross-sectionally, the long-term safety and efficacy of CIPII to intensive subcutaneous insulin therapy using intermittent injections or continuous subcutaneous insulin infusion. Finally, we examined the relationship between glycated hemoglobin levels and the standard deviation of daily blood glucose excursion. Results Cross-sectional analysis revealed similar degrees of metabolic control accompanied by significantly decreased rates of both ketoacidosis (0.013 events/patient/year) and severe hypoglycemia (0.05 events/patient/year) during CIPII compared to intermittent injections and continuous subcutaneous insulin infusion therapy. A four-fold decrease in the rate of severe hypoglycemia was observed during longitudinal comparison of pre- and post-implantation complication rates. A relationship was also shown between decreased levels of mean glycated hemoglobin and the standard deviation of blood glucose excursions during CIPII therapy. Conclusions Our data demonstrate that long-term therapy with CIPII is as effective as other methods in achieving near-normal levels of glycated hemoglobin, which in CIPII is associated with a decreased standard deviation of blood glucose excursions. Further, CIPII using implantable programmable insulin delivery systems is the safest method described for intensive insulin therapy in home blood glucose monitoring type 1 diabetic patients.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3