Comparison of methods to estimate haemodialysis urea clearance

Author:

Mohamed Ahmed1,Davenport Andrew1

Affiliation:

1. UCL Centre for Nephrology, Royal Free Hospital, University College London Medical School, London, UK

Abstract

Introduction: Dialysis adequacy is traditionally measured by monthly blood urea sampling and calculating sessional Kt/Vurea. Modern dialysis machines can estimate clearances each session, so we wished to compare online measurements with standard Kt/Vurea. Methods: Urea clearance was estimated by intermittent changes in effective ionic dialysance and by continuous ultraviolet light absorption spent during the mid-week dialysis session. Total body water was calculated by the Watson equation and measured by multifrequency bioimpedance. Results: We compared Kt/Vurea measurements in 162 patients with online assessments: 38 by ultraviolet absorption and 124 by effective ionic dialysance (50 Fresenius 4008 and 74 Fresenius 5008). All online measurements overestimated single-pool Kt/Vurea (ultraviolet absorption mean bias 0.25 ± 0.24, effective ionic dialysance 4008H 0.25 ± 0.21 and 5008H 0.20 ± 0.25; p < 0.001). However, there was no difference between dual-pool Kt/V and ultraviolet absorbance (1.28 ± 0.26 vs 1.29 ± 0.27) or by effective ionic dialysance with the 4008 (1.40 ± 0.26 vs 1.46 ± 0.33), although the effective ionic dialysance 5008 overestimated clearance (1.39 ± 0.27 vs 1.31 ± 0.22; p < 0.01). Similarly, with dual-pool Kt/Vurea, the mean bias for ultraviolet absorption was 0.08 ± 0.35, for effective ionic dialysance (EID) 4008 was 0.13 ± 0.55 and for EID 5008 was −0.2 ± 0.36. Hence, the mean bias was greater with the EID 5008 compared to ultraviolet absorption (0.08 ± 0.35 vs −0.2 ± 0.36 vs p < 0.01). Conclusions: Online measurements allow dialysis adequacy to be measured every session. We found that although online clearances overestimated single-pool Kt/Vurea measurements, there were no significant differences between the continuous ultraviolet light absorbance method and intermittent effective ionic dialysance.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3