An analytic method to investigate hemodynamics of the cardiovascular system: Biventricular system

Author:

Zhu Yuxin1ORCID,Mei Xu2,Ge Wanning1,Wu Tingting1ORCID,Zhang Liudi1ORCID,Hsu Polin13

Affiliation:

1. Artificial Organ Laboratory, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China

2. State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China

3. magAssist, Co., Ltd., Suzhou, China

Abstract

Previously, we found analytic solutions for single ventricular system based on the lumped parameter model (LPM). In this study, we generalized the method to biventricular system and derived its analytic solutions. LPM is just a set of differential equations, but it is difficult to solve due to time-varying ventricular elastance and high order. Mathematically, there exist no elementary solutions for time-varying equations. It turns out that instead of differential equations, according to volume conservation, a set of algebraic equations can be carried out. The solutions of the set of equations are just physiological states at end of systolic and diastolic phases such as end systolic/diastolic pressure/volume of left ventricle. As a preliminary application, the method is utilized to deduce the hemodynamic effects of VA ECMO. Left ventricular (LV) distension, a serious complication of VA ECMO, is usually attributed to factors such as increased afterload, inadequate LV unloading, reduced myocardial contractility or aortic valve regurgitation (AR), bronchial and Thebesian return in the absence of aortic valve (AoV) opening. Among these, reduced contractility and AR are strongly associated with LV distension. However, in the absence of reduced contractility or AR, it is less clear whether increased afterload or inadequate LV unloading alone can cause LV distension. This leads to the critical question: under what conditions does LV distension occur in the absence of reduced contractility or AR? The analytic formulas derived in this study give conditions for LV distension. Furthermore, the results show that the analytic hemodynamics are coincident with simulated results.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3