The effects on hemostasis of two high-flux membranes in hollow-fiber configuration, polyamide (PAM) and polyacrylonitrile (AN69), were analyzed in a cross-over study involving ten chronic hemodialyzed patients. Blood samples were obtained at arterial and venous sites of the extracorporeal circuit before dialysis and at 15, 30 and 180 min. Primary hemostasis: PAM induced an early significant drop in platelet counts, but at 180 min there was no longer any difference between membranes. Beta-thromboglobulin release by PAM was significantly higher at all time points. Coagulation: thrombin-antihrombin III complexes (TAT) and fibrinopeptide A increased significantly, the highest values being found with AN69. With both membranes the arteriovenous differences in TAT levels were negative throughout the sessions. Fibrinolysis: no significant differences were observed. In conclusion, both membranes induced hemostatic changes. Although these two hollow-fiber dialyzers look relatively similar, the changes observed were different, polyamide acting mainly on primary hemostasis and polyacrylonitrile on coagulation.