HPLC Study of Uremic Fluids Related to Optical Dialysis Adequacy Monitoring

Author:

Lauri Kai1,Tanner Risto2,Jerotskaja Jana1,Luman Merike3,Fridolin Ivo1

Affiliation:

1. Department of Biomedical Engineering, Technomedicum, Tallinn University of Technology, Tallinn

2. Laboratory of Chemical Physics, National Institute of Chemical Physics and Biophysics, Tallinn

3. Department of Dialysis and Nephrology, North Estonia Medical Centre, Tallinn - Estonia

Abstract

Purpose The aim of this study was to investigate uremia-related high-performance liquid chromatography (HPLC) ultraviolet (UV) absorbance profiles of serum and spent dialysate and to study the removal of uremic retention solutes in connection with optical dialysis adequacy monitoring. Methods 10 uremic patients were investigated using online spectrophotometry at a wavelength of 280 nm over the course of 30 hemodialysis treatments. The dialysate and blood samples were taken and analyzed simultaneously using standard biochemical methods and reversed-phase HPLC. Filters with cutoff at 3 kDa and 70 kDa were used for the pre-treatment of the serum. The chromatographic peaks were detected by a UV detector at wavelengths of 254 and 280 nm. Results This study indicated that the main solute responsible for UV absorbance in the spent dialysate is a low-molecular-weight, water-soluble, non-protein-bound compound uric acid (UA). Three additional uremic retention solutes – creatinine (CR), indoxyl sulphate (IS) and hippuric acid (HA) – were identified from the HPLC profiles. The number of detected HPLC peaks was not significantly different for a serum filtered through the 3 kDa or 70 kDa cutoff filters, and was lower for the spent dialysate, indicating that the molecular weight (MW) of the main UV chromophores in the uremic fluids did not exceed 3 kDa. The reduction ratio (RR) estimated by the total area of HPLC peaks at 254 nm and 280 nm in the serum and by the online UV absorbance at 280 nm was best related to the removal of small water-soluble non-protein bound solutes like urea (UR), CR and UA. Conclusions The present study contributes new information on the removal of uremic retention solutes during hemodialysis and on the origin of the optical dialysis adequacy monitoring signal.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3