Abstract

Aims: To investigate if a single low-flux HD induces a rise in cardiac biomarkers and if a change in clinical approach may limit such mechanism. Material and methods: A total of 20 chronic HD patients each underwent three different study-dialyses. Dialyzers (low-flux polysulfone, 1.8 sqm) had been stored either dry or wet (Wet) and the blood level in the venous chamber kept low or high. Laboratory results were measured at baseline, 30 and 180 min, adjusted for the effect of fluid shift. Ultrasound measured microemboli signals (MES) within the return line. Results: Hemodialysis raised cardiac biomarkers ( p < 0.001): Pentraxin 3 (PTX) at 30 min (by 22%) and at 180 min PTX (53%), Pro-BNP (15%), and TnT (5%), similarly for all three HD modes. Baseline values of Pro-BNP correlated with TnT (rho = 0.38, p = 0.004) and PTX (rho = 0.52, p < 0.001). The changes from pre- to 180 min of HD ( delta-) were related to baseline values (Pro-BNP: rho = 0.91, p < 0.001; TnT: rho = 0.41, p = 0.001; PTX: rho = 0.29, p = 0.027). Delta Pro-BNP (rho = 0.67, p < 0.001) and TnT (rho = 0.38, p = 0.004) correlated with inter-dialytic-weight-gain (IDWG). Biomarkers behaved similarly between the HD modes. The least negative impact was with an IDWG ⩽ 2.5%. Multiple regression analyses of the Wet-High mode does not exclude a relation between increased exposure of MES and factors such as release of Pro-BNP. Conclusion: Hemodialysis, independent of type of dialyzer storage, was associated with raised cardiac biomarkers, more profoundly in patients with higher pre-dialysis values and IDWG. A limitation in IDWG to <2.5% and prolonged ultrafiltration time may limit cardiac strain during HD, especially in patients with cardiovascular risk.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3