The alterations of cardiac function during venovenous artificial placenta support in fetal goats

Author:

Li Guanhua12ORCID,Li Mingliang13,Teng Yun1,Zhang Li1,Pang Chengcheng4,Tan Jianfeng5,Chen Jimei1,Zhuang Jian1,Zhou Chengbin1

Affiliation:

1. Department of Cardiovascular Surgery, Guangdong Provincial Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China

2. Department of Cardiovascular Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China

3. Department of Cardio-Thoracic Surgery, Affiliated Hospital of Guangdong Medical University, Zhanjiang, China

4. Department of Maternal-Fetal Cardiology, Guangdong Provincial Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China

5. Department of Thoracic Surgery, Shenzhen Hospital, Southern Medical University, Shenzhen, China

Abstract

Introduction: Venovenous artificial placenta (VVAP) may mimic the intrauterine environment for maintaining fetal circulation. However, changes in ventricular function in fetal goats undergoing VVAP support remain unclear. Methods: Pump-assisted VVAPs were established in five fetal goats for 9 h. The myocardial performance index (Tei index), cardiac output (CO), and blood biochemical parameters were measured during VVAP support. Results: An increasing trend of the right ventricular (RV) Tei index was seen during VVAP support ( p for trend < 0.01). The right ventricular cardiac output (RVCO) increased after the initiation of VVAP, while a significant trend of reduction was observed after 3 h ( p for trend = 0.03). During VVAP support, we observed remarkable elevations of plasma cTnI and arterial lactic acid, which were positively correlated with the RV Tei index, but not the left ventricular (LV) Tei index, LVCO, and RVCO. Conclusions: The RVCO increases initially while a tendency of decrease could be observed during VVAP support. Special attention should be paid to right ventricular dysfunction during VVAP support.

Funder

Guangdong Basic and Applied Basic Research Foundation

Guangdong Science and Technology Project

National Key Project of Research and Development

China Postdoctoral Science Foundation

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering