Affiliation:
1. Akdeniz University, Antalya, Turkey
Abstract
Noise is a significant problem for both hospitalized patients and health care workers. This study aimed to determine the effectiveness of noise reduction strategies in an intensive care unit. Noise was measured in two phases. In the first phase, the unit’s present level of noise was established over 3 weeks between January 1, 2012, and February 1, 2012. During the month following initial measurements, noise reduction interventions, including staff education and physical space arrangement, were initiated, and device alarms were checked. The second phase of measurement was conducted during another 3-week period (between June 1, 2012, and July 1, 2012). The noise levels before and after noise reduction interventions were calculated as 67.6 dB-A and 56 dB-A; the difference between the two levels was statistically significant ( p < .05). The interventions were effective in reducing noise in intensive care units; the interventions are relatively easy and low cost.
Subject
Nursing (miscellaneous),Public Health, Environmental and Occupational Health
Cited by
23 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献