Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins

Author:

Lee Kyung-Hag1,Lee Yohan2ORCID,Lee Young Ho3,Cho Bong Wan4,Kim Min Bom3,Baek Goo Hyun3

Affiliation:

1. Department of Orthopedic Surgery, National Medical Center, Seoul, South Korea

2. Department of Orthopedic Surgery, Seoul National University Boramae Hospital, Seoul, South Korea

3. Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea

4. Department of Orthopedic Surgery, Seoul Jaeil Hospital, Pyeongtaek, South Korea

Abstract

Purpose: The purpose of this study is to compare biomechanical characteristics of tension band wiring using Kirschner wires (TBWKW), cannulated screws (TBWCS), and ring pins (TBWRP) for transverse fracture of the patella. Methods: A total of 48 polyurethane synthetic patellae were biomechanically tested. All patellae were osteotomized to create a transverse fracture. Each TBWKW, TBWCS, and TBWRP fixed 16 broken patellae. A specially designed fixation board simulated a knee with 90° flexion. Ten static tests and six dynamic tests were performed on each method. The static test is measuring maximum strength ( N) during traction until breakage of the fixation. The dynamic test consisted of measuring the fracture gap (mm) after 10,000 repetitive loading cycles between 100 N and 300 N that simulated actual daily activity. A gap of 2 mm or more was defined as a failure in both tests. Result: The failure load was 438.6 ± 138.6 N, 422.2 ± 72.7 N, and 1106.8 ± 230.3 N for TBWKW, TBWRP, and TBWCS, respectively. TBWCS showed a statistically significant difference compared to TBWKW and TBWRP in the static test ( p < 0.001). All the groups had no failure in the dynamic test. The mean fracture gap after completion of the dynamic test was 0.3267 ± 0.3395 mm, 0.2938 ± 0.2165 mm, and 0.0360 ± 0.0570 mm for TBWKW, TBWRP, and TBWCS, respectively ( p = 0.044). The mean values in the dynamic test showed no statistical difference. There was a significant difference between TBWRP and TBWCS ( p = 0.009), but others showed no difference with statistical significance. Conclusion: All three methods have sufficient stability at a daily activity. TBWCS showed a better failure load compared with TBWKW and TBWRP. TBWRP showed compatible mechanical characteristics with traditional tension band wiring. TBWRP could be an alternative method for TBWKW.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3