Does using high-tensile strength tape improve the fixation strength in tendon graft fixation with needleless suture wrapping techniques compared to a suture?

Author:

Hong Chih-Kai1,Kuan Fa-Chuan12,Hsu Kai-Lan12,Chen Yueh3,Chuang Hao-Chun1,Chiang Chen-Hao24,Su Wei-Ren156ORCID

Affiliation:

1. Department of Orthopaedic Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan

2. Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan

3. Department of Orthopaedic Surgery, Sin Lau Hospital, Tainan, Taiwan

4. Department of Orthopaedics, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan

5. Skeleton Materials and Bio-compatibility Core Lab, Research Center of Clinical Medicine, National Cheng Kung University Hospital, Tainan, Taiwan

6. Musculoskeletal Research Center, Innovation Headquarter, National Cheng Kung University, Tainan, Taiwan

Abstract

Purpose: To compare the biomechanical properties of a high-tensile strength suture and high-tensile strength tape in tendon graft fixation using two needleless suture wrapping techniques, the modified Prusik knot and modified rolling hitch. Methods: Two needleless suture wrapping techniques, the modified rolling hitch (MR) and modified Prusik knot (MP), were utilized. Meanwhile, two kinds of suture materials, a No. 2 braided nonabsorbable high-strength suture (S) and a 1.3 mm high-tensile strength tape (T), were used. A total of 40 porcine tendons were used, which were randomly divided into four groups. Each group was assigned to one of the following groups: MRS, MRT, MPS, and MPT. Each specimen was pretensioned to 100 N for three cycles, cyclically loaded from 50 to 200 N for 200 cycles, and finally loaded to failure. Results: The MRT group (34.1 ± 3.5%) had a significantly higher value compared with the MRS (29.7 ± 2.3%), MPS (27.1 ± 3.6%) and MPT (29.5 ± 4.0%) groups in term of elongation after cyclic loadings ( p = 0.002). In terms of ultimate failure load, there were no significant differences in the MRS (401 ± 27 N), MRT (380 ± 27 N), MPS (398 ± 44 N) and MPT (406 ± 49 N) values ( p = 0.539). All specimens failed due to suture breakage at the knots. Conclusion: Compared with the high-tensile strength suture, using the high-tensile strength tape lead to greater elongation after cyclic loading when the modified rolling hitch was used. No differences in terms of elongation after cyclic loading and load to failure were found between the high-tensile strength suture and tape using the modified Prusik knot.

Funder

Ministry of Science and Technology, Taiwan

Publisher

SAGE Publications

Subject

Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3