Cephalomedullary Nail versus Sliding Hip Screw for Unstable Intertrochanteric Fractures in Elderly Patients

Author:

Chua Ivan Tjun Huat1,Rajamoney Ganesan Naidu1,Kwek Ernest Beng Kee1

Affiliation:

1. Department of Orthopaedic Surgery, Tan Tock Seng Hospital, Singapore

Abstract

Purpose. To compare the short-term ambulatory function of elderly patients after fixation of unstable intertrochanteric fractures with either the AO-ASIF proximal femoral nail anti-rotation (PFNA) device or the dynamic hip screw (DHS). Methods. 63 patients aged ≥60 years underwent fixation for unstable intertrochanteric fractures (AO types A2 and A3) using the PFNA (n=25) or DHS (n=38). The decision for the type of implant used was based on the lead surgeon's preference, according to perceived fracture stability and clinical experience. In patients having PFNA fixation, weight bearing ambulation and rehabilitation was commenced on day 2. The extent of weight bearing was decided by the lead surgeon based on the stability of the fracture. In patients having DHS fixation, non-weight bearing and ambulation with a walking aid was commenced on day 2. Ambulatory function before injury and after surgery was measured using the Parker Mobility Score (PMS). The 2 groups were compared in terms of the PMS, ambulatory independence, and environmental mobility. Results. Respectively in PFNA and DHS patients, 32% and 13% (p=0.035) were ambulant with a walking frame at discharge; the remainder were wheelchair bound. Patients treated with PFNA had significantly higher median PMS at 6 months (4 vs. 2, p=0.002), median ambulatory independence score at 6 months (4 vs. 3, p=0.004) and at 12 months (5 vs. 4, p=0.001), and median environmental mobility score at 6 months (2 vs. 1, p=0.007). They also had significantly higher percentage of patients able to ambulate outdoor and in community at 6 months (64% vs. 29%, p=0.02) and able to walk independently or with a walking aid at 12 months (96% vs. 69%, p=0.01). There were 3 complications. Two patients treated with PFNA had blade cut-out, owing to poor fracture reduction. One patient treated with DHS had screw cut-out and subsequently developed avascular necrosis of the femoral head. Conclusion. Unstable intertrochanteric fractures in elderly patients with good pre-fracture ambulatory function stabilised with the PFNA resulted in better short-term ambulatory function.

Publisher

SAGE Publications

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3